Biocompatibility of orthodontic adhesives in rat subcutaneous tissue
نویسندگان
چکیده
OBJECTIVE The objective of the present study was to verify the hypothesis that no difference in biocompatibility exists between different orthodontic adhesives. MATERIAL AND METHODS Thirty male Wistar rats were used in this study and divided into five groups (n=6): Group 1 (control, distilled water), Group 2 (Concise), Group 3 (Xeno III), Group 4 (Transbond XT), and Group 5 (Transbond plus Self-Etching Primer). Two cavities were performed in the subcutaneous dorsum of each animal to place a polyvinyl sponge soaked with 2 drops of the respective adhesive in each surgical loci. Two animals of each group were sacrificed after 7, 15, and 30 days, and their tissues were analyzed by using an optical microscope. RESULTS At day 7, Groups 3 (Transbond XT) and 4 (Xeno III) showed intense mono- and polymorphonuclear inflammatory infiltrate with no differences between them, whereas Groups 1 (control) and 2 (Concise) showed moderate mononuclear inflammatory infiltrate. At day 15, severe inflammation was observed in Group 3 (Transbond XT) compared to other groups. At day 30, the same group showed a more expressive mononuclear inflammatory infiltrate compared to other groups. CONCLUSION Among the orthodontic adhesive analyzed, it may be concluded that Transbond XT exhibited the worst biocompatibility. However, one cannot interpret the specificity of the data generated in vivo animal models as a human response.
منابع مشابه
Biocompatibility of eight different orthodontic materials: in-vivo rat model study
Biocompatibility of eight different orthodontic materials: in-vivo rat modl study Dr. Sadeghian, S.* - Dr. Razavi, S.M. ** - Dr. Masaeli, A.*** *Assistant Professor of Orthodontics Dept., Faculty of Dentistry, Isfahan Azad University (Khorasgan). **Assistant Professor of Pathology Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ***Dentist. Abstract Background & Aim: Differe...
متن کاملBiocompatibility comparison of two different sealers AH26 and Apexit: In-vivo animal model
Biocompatibility comparison of two different sealers AH26 and Apexit: In-vivo animal model Dr. Zare Jahromi, M.* - Dr. Razavi, S.M.** - Dr. Tabesh, B.*** *Assistant Professor of Endodontics Dept., Faculty of Dentistry, Isfahan Azad University (Khorasgan). **Assistant Professor of Pathology Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ***Dentist. Abstract Background & Aim...
متن کاملIn vivo qualitative analysis of the biocompatibility of different cyanoacrylate-based adhesives.
Cyanocrylates have been widely used in the medical and dental fields for several years. In Dentistry, cyanoacrylates have been used for suturing, pulp capping, as retrofilling material in endodontic surgeries, and as cervical plug for pulpless teeth bleaching. The biocompatibility of these adhesives has been the topic of many researches and subcutaneous implantation is an effective methodology ...
متن کاملIn vitro biocompatibility of eight orthodontic materials in human oral fibroblasts
In vitro biocompatibility of eight orthodontic materials in human oral fibroblasts Dr. S. Sadeghian* - Dr. MH. Nasr Esfahani** - F. Molavi*** *- Assistant Professor of Orthodontics Dept. - Faculty of Dentistry – Islamic Azad University (Khorasgan). **- Associate Professor of Embryology, Royan Institute, ***- Member of Royan Institute, Background and Aim: In orthodontic therapy, different materi...
متن کامل%Methoxybutylcyanoacrylate: evaluation of biocompatibility and bioresorption
The biocompatibility and bioresorption of 3-methoxybutylcyanoacrylate (MBCA) was evaluated in vivo using female Wistar albino rats. MBCA was found to elicit slight to moderate tissue reaction similar to isobutylcyanoacrylate (IBCA) which has been sold commercially as a surgical adhesive (Bucrylate@, Ethicon). MBCA was judged less reactive to tissue than ethylcyanoacrylate (ECA). The MBCA implan...
متن کامل