Design Considerations for a Conventional Microscope based Microarray-Reader to Improve Sensitivity
نویسنده
چکیده
An unmodified wide-field fluorescence microscope system equipped with a scientific grade CCD camera can be used to measure fluorescent signals in subnanoliter vials. The lowest detectable fluorescence signal in a 0.8nl vial of 200 × 200 × 20μm corresponds to a concentration of fluorescent molecules on the order of a nanomolar (10−9M ) for a dye such as Rhodamine. This paper will explain that the lowest detectable concentration is limited by one of the following instrumental factors: stray light, originating in the excitation path of the microscope system or readout noise in the photon detection part of the system. This paper will present a number of modifications to our wide-field microscope system to improve its performance in terms of the detection limit, under assumption that readout noise is the limiting factor.
منابع مشابه
Oblique-incidence reflectivity difference microscope for label-free high-throughput detection of biochemical reactions in a microarray format.
We describe a recently developed oblique-incidence reflectivity difference (OI-RD) microscope, a form of polarization-modulated imaging ellipsometer, for label-free-high-throughput detection of biomolecular reactions on DNA and protein microarrays. We present examples of application of this technique to end-point and real-time investigations of DNA-DNA hybridization, antibody-antigen capture, a...
متن کاملEffective Design of a 3×4 Two Dimensional Distributed Amplifier Based on Gate Line Considerations
In this paper two dimensional wave propagation is used for power combining in drain nodes of a distributed amplifier (DA). The proposed two dimensional DA uses an electrical funnel to add the currents of drain nodes. The proposed structure is modified due to gate lines considerations. Total gain improvement is achieved by engineering the characteristic impedance of gate lines and also make appr...
متن کاملAudience awareness of Persian learners of English writing: Towards a model of task-oriented strategies
Persian learners of English often avoid attending to audience considerations, which brings them lower scores. The present study was conducted in a major university in Iran to help Persian learners develop a sense of audience awareness in writing. Thirty five Persian students of English were trained with a focus on process-oriented instruction. The intended task was a...
متن کاملCombined Use of Sensitivity Analysis and Hybrid Wavelet-PSO- ANFIS to Improve Dynamic Performance of DFIG-Based Wind Generation
In the past few decades, increasing growth of wind power plants causes different problems for the power quality in the grid. Normal and transient impacts of these units on the power grid clearly indicate the need to improve the quality of the electricity generated by them in the design of such systems. Improving the efficiency of the large-scale wind system is dependent on the control parameter...
متن کاملAn Adaptable, Portable Microarray Reader for Biodetection
We have developed an inexpensive portable microarray reader that can be applied to standard microscope slide-based arrays and other array formats printed on chemically modified surfaces. Measuring only 19 cm in length, the imaging device is portable and may be applicable to both triage and clinical settings. For multiplexing and adaptability purposes, it can be modified to work with multiple ex...
متن کامل