Review of the role of dynamic 18F-NaF PET in diagnosing and distinguishing between septic and aseptic loosening in hip prosthesis

نویسندگان

  • Olu Adesanya
  • Andrew Sprowson
  • James Masters
  • Charles Hutchinson
چکیده

Joint replacements may fail due to infection, dislocation, peri-prosthetic fracture and loosening. Between 0.4 and 4% of joint replacements are known to be complicated by infection and aseptic loosening 2-18%. Differentiating between infection and aseptic loosening has an important bearing on the ongoing strategy for antimicrobial therapy and surgical intervention, but distinguishing one from the other can be difficult and will often require a battery of clinical and biochemical tests including the use of varying radiological modalities to accurately identify whether problematic joints are infected or aseptically loose. Prompt diagnosis is important due to the development of a biofilm on the surface of the infected prosthesis, which makes treatment difficult. There is no consensus among experts on the ideal imaging technique nor the methodology for image interpretation, but there is an increasing trend to apply hybrid imaging in the investigation of painful joint prosthesis and recent attempts have been made using PET-CT to identify aseptic loosening and infection with (18)F-fluorodeoxyglucose (FDG) and sodium fluoride (18)F-Na. The aim of this paper is to evaluate the role of (18)F-NaF sodium fluoride ((18)F-NaF) positron emission tomography (PET) in distinguishing between septic and aseptic failure in hip and knee replacements, in addition to evaluating the feasibility of using multi-sequential (18)F-NaF PET-CT for the assessment of painful lower limb prostheses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Promising Role of Dynamic 18F-NaF PET-CT in Diagnosing Symptomatic Joint Prosthesis Integrative Biomedical Sciences

Our purpose was to establish proof of principle case study for the use of dynamic 18F-NaF PET-CT in the assessment of knee and hip prostheses. Approval was granted by the research ethics committee and informed consent was obtained. This is a case study investigating the role of dynamic 18F NaF PET-CT in a patient with bilateral knee prostheses (1 symptomatic/painful and 1 asymptomatic). Both kn...

متن کامل

The implications of 18F-FDG PET for the diagnosis of endoprosthetic loosening and infection in hip and knee arthroplasty: Results from a prospective, blinded study

BACKGROUND The most frequent complications of joint arthroplasty are septic or aseptic loosening of endoprostheses. Preoperative differentiation is essential, since very different treatment methods result from the diagnoses. The aim of the current study was to evaluate the clinical value of 18F-Fluoro-deoxyglucose positron emission tomography (18F-FDG PET) as a diagnostic modality for inflammat...

متن کامل

The role of nuclear medicine techniques in differentiation between septic and aseptic loosening of total hip and knee arthroplasty

Jansen JA, Smit F, Pereira Arias-Bouda LM. The role of nuclear medicine techniques in differentiation between septic and aseptic loosening of total hip and knee arthroplasty. This article gives an overview of nuclear imaging techniques, which can be used to diagnose (a)septic loosening in joint replacements. The pathophysiology of loosening and the differences between septic and aseptic looseni...

متن کامل

Metabolic Pattern of Asymptomatic Hip-Prosthesis by 18F-FDG-Positron-Emission-Tomography

BACKGROUND Joint replacement is a procedure with a major impact on the quality of life of patients with joint degenerative disease or traumatic injuries. However, some patients develop symptoms after the intervention caused by mechanical loosening or infection. Metabolic imaging by 18F-FDG-PET investigated in these patients isoften hampered by low specificity for diagnosis of possible septic vs...

متن کامل

An assessment of the histological criteria used to diagnose infection in hip revision arthroplasty tissues.

AIM To characterise the number and nature of the inflammatory cells seen in cases of septic or aseptic loosening of hip arthroplasty, and to establish reliable histological criteria to distinguish between these two conditions. METHODS Histological examination of paraffin sections of periprosthetic tissues (pseudocapsule, femoral and acetabular pseudomembranes) of 523 cases of aseptic loosenin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015