Fast time-resolved cine sequence using temporal regularization for small animal cardiac imaging on a clinical 3T scanner
نویسندگان
چکیده
B. Delattre, V. Braunersreuther, J-N. Hyacinthe, J-P. Vallée, and D. Van De Ville University of Geneva Faculty of medicine, Geneva, Switzerland, Division of Cardiology Department of Medicine, Geneva University Hospital Foundation for medical researchers, Geneva, Switzerland, Department of Radiology and Medical Informatics University of Geneva, Geneva, Switzerland, Institute of Bioengineering Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
منابع مشابه
On Motion Estimation and Compensation Baseline Estimations in Dynamic Imaging: a Comparative Study with Cine Cardiac and Contrast-Enhanced Lung Imaging
Introduction: Estimation of the baseline in a dynamic imaging series is an essential step in compressed-sensing-based acceleration methods for MRI acquisition [1,2], as an accurate baseline estimation helps sparsifying the remaining residues effectively. Recent literatures suggest improved baseline estimation using adaptive regularization [1] or motion estimation (ME) and motion compensation (M...
متن کاملLeft Ventricular Function Evaluation on a 3T MR Scanner with Parallel RF Transmission Technique: Prospective Comparison of Cine Sequences Acquired before and after Gadolinium Injection
OBJECTIVES To compare cine MR b-TFE sequences acquired before and after gadolinium injection, on a 3T scanner with a parallel RF transmission technique in order to potentially improve scanning time efficiency when evaluating LV function. METHODS 25 consecutive patients scheduled for a cardiac MRI were prospectively included and had their b-TFE cine sequences acquired before and right after ga...
متن کاملCine interleaved sequences enabled imaging of mice on clinical 3T MRI and analysis of their cardiac function after myocardial infarction
Background With the poor availability of small animal dedicated MRI, it is of great interest and challenge to use clinical MRI to image and analyze the cardiac function of mice. This would of course be advantageous for translational research and also enable the use of up-to-date sequences already implemented in clinical routine. The aim is to study the time evolution of cardiac function in mice...
متن کاملECG/Navigator-Free 4D Whole-Heart Coronary MRA with Simultaneous Visualization of Cardiac Function and Anatomy
Purpose: Cardiac and respiratory motion artifacts are major challenges in cardiac MRI, and are conventionally suppressed by prospective ECG and diaphragm navigator gating, respectively. However, these approaches require time-consuming setup and prolonged acquisition times, and are susceptible to variations of heart rate or respiratory pattern. Further, they can become unreliable at higher field...
متن کامل3D Cardiac Cine Imaging Using a 3D Cones Trajectory
Introduction: Cine imaging is a widely accepted clinical tool for assessing cardiac wall motion and performing volume measurements. Conventional cine sequences acquire multiple cardiac phases of a single 2D slice during a breathheld scan, with multiple slices collected over multiple breath-holds. While respiratory artifacts are minimized and the temporal resolution is high for each slice, it ca...
متن کامل