Exhaled nitric oxide in mylar balloons: influence of storage time, humidity and temperature.
نویسندگان
چکیده
BACKGROUND Mylar balloons are used to collect exhaled air for analysis of fractional nitric oxide concentration (FENO). AIM We studied the effect of storage conditions on the stability of nitric oxide (NO) in mylar balloons. METHODS Exhaled air samples and calibration gases were stored in mylar balloons at 4, 21 and 37 degrees C, with or without silica gel. NO was measured after 0, 6, 9, 24 and 48 h. Scheffe F-tests were used to compare NO values. RESULTS NO remained stable in balloons for 9 h at all temperatures, without silica gel. NO increased between 9 and 48 h, but only with low initial FENO. Silica gel increased variability. CONCLUSIONS FENO in mylar balloons is stable for at least 9 h. The storage temperature is not critical, but silica gel increases variability.
منابع مشابه
A method for the standardized offline collection of exhaled nitric oxide.
STUDY OBJECTIVES Exhaled nitric oxide (ENO) is a noninvasive marker of airway inflammation. The purpose of this study was to compare a standardized offline ENO measurement apparatus with a validated on-line method. DESIGN Asthmatic volunteers (n = 21) had ENO measured by the two following methods: (1) inhalation to total lung capacity (TLC) followed by exhalation at a constant flow (45 mL/s) ...
متن کاملStorage conditions for stability of offline measurement of fractional exhaled nitric oxide after collection for epidemiologic research
BACKGROUND The measurement of fractional concentration of nitric oxide in exhaled air (FeNO) is valuable for the assessment of airway inflammation. Offline measurement of FeNO has been used in some epidemiologic studies. However, the time course of the changes in FeNO after collection has not been fully clarified. In this study, the effects of storage conditions on the stability of FeNO measure...
متن کاملOff-line sampling of exhaled air for nitric oxide measurement in children: methodological aspects.
Measurement of nitric oxide in exhaled air is a noninvasive method to assess airway inflammation in asthma. This study was undertaken to establish the reference range of exhaled NO in healthy school-aged children and to determine the influence of ambient NO, noseclip and breath-holding on exhaled NO, using an off-line balloon sampling method. All children attending a primary school (age range 8...
متن کاملSampling of exhaled nitric oxide in children: end-expiratory plateau, balloon and tidal breathing methods compared.
The aim of this study was to compare exhaled nitric oxide concentrations obtained during controlled slow exhalation, presently considered as the method of choice, with two sampling methods that are easily performed by children: blowing air into a balloon and tidal breathing through a mouthpiece. One hundred and one well controlled, stable allergic asthmatic children (median age 11.7 yrs) perfor...
متن کاملExhaled nitric oxide measurements with dynamic flow restriction in children aged 4-8 yrs.
Fractional exhaled nitric oxide concentration (FENO) depends on exhalation flow; however, children often are unable to perform controlled flow procedures. Therefore, a device was developed for off-line FENO sampling, with dynamic flow restriction (DFR). The authors compared off-line with on-line FENO, assessed feasibility, and obtained normal values for FENO in children aged 4-8 yrs. Subjects i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Mediators of Inflammation
دوره 12 شماره
صفحات -
تاریخ انتشار 2003