Spectrophotometric Assay of Phenylephrine Hydrochloride Using 4-Aminoantipyrine and Copper (II)
نویسنده
چکیده
A new spectrophotometric method is proposed for the determination of phenylephrine hydrochloride. The method is based on the coupling of 4-aminoantipyrine (4-AAP) with Phenylephrine Hydrochloride (PEH) to give a new ligand that reacts with copper (II) in the presence of sodium tetraborate buffer solution of pH9 at 50°C with an intensely red colored chelate having maximum absorption at 480 nm. The method has been used for the determination of 2.0–50.0 μg ml-1 of PEH with molar absorptivity of 5.357×103 L.mol-1cm-1, average recovery of 101.28 % and Relative Standard Deviation (RSD) of 1.25%. The results of the method were compared with those of the official method. The mechanism of the chemical reaction has been proposed. The proposed method was successfully applied for the determination of the PEH in pharmaceutical syrup formulations.
منابع مشابه
Spectrophotometric determination of phenylephrine hydrochloride in pharmaceuticals by flow injection analysis exploiting the reaction with potassium ferricyanide and 4-aminoantipyrine.
This paper presents a method for the determination of phenylephrine hydrochloride in pharmaceuticals by spectrophotometric flow injection analysis exploiting the reaction with potassium ferricyanide and 4-aminoantipyrine, which leads to the formation of a condensation product with strong absorptivity at 500 nm. The linear dynamic range was between 0.95 and 9 mg/L, with a limit of detection of 0...
متن کاملSpectrophotometric Analysis of Vardenafil in Tablet Dosage Forms by Using Electrophilic Coupling Reagents
Two new spectrophotometric methods (M1 and M2) are developed for the determination of vardenafil in bulk and in tablet dosage forms. The method M1 involves oxidative coupling of vardenafil with 3-methyl-2-benzothiazolinone hydrazone hydrochloride in presence of ferric chloride in acidic medium yielding green colored chromogen with absorption maxima at 625 nm. The method M2 is based on the oxida...
متن کاملA Peroxidase-linked Spectrophotometric Assay for the Detection of Monoamine Oxidase Inhibitors
To develop a new more accurate spectrophotometric method for detecting monoamine oxidase inhibitors from plant extracts, a series of amine substrates were selected and their ability to be oxidized by monoamine oxidase was evaluated by the HPLC method and a new substrate was used to develop a peroxidase-linked spectrophotometric assay. 4-(Trifluoromethyl) benzylamine (11) was proved to be an exc...
متن کاملA Peroxidase-linked Spectrophotometric Assay for the Detection of Monoamine Oxidase Inhibitors
To develop a new more accurate spectrophotometric method for detecting monoamine oxidase inhibitors from plant extracts, a series of amine substrates were selected and their ability to be oxidized by monoamine oxidase was evaluated by the HPLC method and a new substrate was used to develop a peroxidase-linked spectrophotometric assay. 4-(Trifluoromethyl) benzylamine (11) was proved to be an exc...
متن کاملSpectrophotometric determination of ritodrine and isoxsuprine hydrochlorides using 4-aminoantipyrine.
A simple, accurate, and rapid method for the quantitative determination of ritodrine hydrochloride (RTH) and isoxsuprine hydrochloride (ISH) in both pure and dosage forms, is described. The method is based on the development of pink colored product as a result of the condensation of 4-aminoantipyrine with phenols in the presence of an alkaline oxidizing agent. The resulting products are measure...
متن کامل