3D computerized occlusion rating of embolized experimental aneurysms using noninvasive 1.5T MR imaging.

نویسندگان

  • C Sherif
  • S Marbacher
  • J Fandino
  • S Erhardt
  • V Neuschmelting
  • M Killer
  • G Mach
  • L Remonda
چکیده

BACKGROUND AND PURPOSE For embolized cerebral aneurysms, the initial occlusion rate is the most powerful parameter to predict aneurysm rerupture and recanalization. However, the occlusion rate is only estimated subjectively in clinical routine. To minimize subjective bias, computer occlusion-rating (COR) was successfully validated for 2D images. To minimize the remaining inaccuracy of 2D-COR, COR was applied to 1.5T 3D MR imaging. MATERIALS AND METHODS Twelve experimental rabbit aneurysms were subjected to stent-assisted coil embolization followed by 2D DSA and 3D MR imaging. Subjective occlusion-rate (SOR) was estimated. Linear parameters (aneurysm length, neck width, parent vessel diameter) were measured on 2D DSA and 3D MR imaging. The occlusion rate was measured by contrast medium-based identification of the nonoccluded 2D area/3D volume in relation to the total aneurysm 2D area/3D volume. 2D and 3D parameters were statistically compared. RESULTS There were no limiting metallic artifacts by using 3D MR imaging. Linear parameters (millimeters) were nearly identical on 2D DSA and 3D MR imaging (aneurysm length: 7.5 ± 2.6 versus 7.4 ± 2.5, P = .2334; neck width: 3.8 ± 1.0 versus 3.7 ± 1.1, P = .6377; parent vessel diameter: 2.7 ± 0.6 versus 2.7 ± 0.5, P = .8438), proving the high accuracy of 3D MR imaging. COR measured on 3D MR imaging was considerably lower (61.8% ± 26.6%) compared with the following: 1) 2D-COR (65.6% ± 27.1%, P = .0537) and 2) 2D-SOR estimations (69.2% ± 27.4%, P = .002). These findings demonstrate unacceptable bias in the current clinical standard SOR estimations. CONCLUSIONS 3D-COR of embolized aneurysms is easily feasible. Its accuracy is superior to that of the clinical standard 2D-SOR. The difference between 3D-COR and 2D-COR approached statistical significance. 3D-COR may add objectivity to the ability to stratify the risk of rerupture in embolized cerebral aneurysms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Follow-up of coiled intracranial aneurysms: comparison of 3D time-of-flight MR angiography at 3T and 1.5T in a large prospective series.

BACKGROUND AND PURPOSE Our aim was to compare 3D TOF-MRA sequences at 3T and 1.5T in the follow-up of coiled aneurysms. The follow-up of coiled intracranial aneurysms is mandatory to depict potential recanalization. 3D-TOF MRA is an appropriate tool for this purpose. MATERIALS AND METHODS DSA and 3D TOF-MRA at 1.5T and 3T were performed in a prospective series of 126 aneurysms in 96 patients ...

متن کامل

Computerized Angiographic Occlusion Rating for Ruptured Clipped Aneurysms is Superior to Subjective Occlusion Rating.

BACKGROUND AND PURPOSE The computerized occlusion rating to estimate angiographic occlusion of embolized aneurysms is superior to the subjective occlusion rating. In this study, we compared the 2 methods in the analysis of aneurysms clipped after subarachnoid hemorrhage. MATERIALS AND METHODS The pre- and postoperative angiographic images (DSA) of 95 selected patients were analyzed and strati...

متن کامل

Computerized assessment of angiographic occlusion rate and coil density in embolized human cerebral aneurysms.

BACKGROUND AND PURPOSE Computerized methods have been introduced for more objective quantification of angiographic occlusion rate and coil density as parameters of successful embolization. This study aimed 1) to evaluate this new computerized method for angiographic occlusion rating and coil density calculations by comparison with corresponding histometric parameters from retrieved human aneury...

متن کامل

A prospective trial of 3T and 1.5T time-of-flight and contrast-enhanced MR angiography in the follow-up of coiled intracranial aneurysms.

BACKGROUND AND PURPOSE Endovascularly coiled intracranial aneurysms are increasingly being followed up with noninvasive MRA imaging to evaluate for aneurysm recurrences. It has not been well-established which MRA techniques are best for this application, however. Our aim was to prospectively compare 4 MRA techniques, TOF and CE-MRA at 1.5T and 3T, to a reference standard of DSA in the evaluatio...

متن کامل

A comparison between magnetic resonance angiography at 3 teslas (time-of-flight and contrast-enhanced) and flat-panel digital subtraction angiography in the assessment of embolized brain aneurysms

PURPOSE To compare the time-of-flight and contrast-enhanced- magnetic resonance angiography techniques in a 3 Tesla magnetic resonance unit with digital subtraction angiography with the latest flat-panel technology and 3D reconstruction in the evaluation of embolized cerebral aneurysms. INTRODUCTION Many embolized aneurysms are subject to a recurrence of intra-aneurismal filling. Traditionall...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 33 4  شماره 

صفحات  -

تاریخ انتشار 2012