Improved analysis for urinary polyamines by use of high-voltage electrophoresis on paper.

نویسندگان

  • K Fujita
  • T Nagatsu
  • K Shinpo
  • K Maruta
  • R Teradaira
  • M Nakamura
چکیده

This method for assay of polyamines (putrescine, spermidine, and spermine) in large numbers of urine samples is based on preliminary analyte isolation by use of a Dowex 50W column, separation by high-voltage paper electrophoresis, reaction with ninhydrin to detect the separated amines, and subsequent direct assay with a dual-wave-length thin-layer chromatography scanner by the zigzag scanning method. By optimizing the conditions for the Dowex 50W column and high-voltage paper electrophoresis, putrescine, cadaverine, spermidine, and spermine were completely separated. The major technical improvements are room-temperature collection of urine with toluene, shorter hydrolysis time, complete separation of putrescine from cadaverine and histamine, and elimination of interference with spermine measurement. Polyamine concentrations as measured by this method agreed with those obtained by use of an amino acid analyzer. Reference intervals by this method were similar to those reported by Russell (Clin. Chem. 23: 22, 1977) with an automated amino acid analyzer. Putrescine, spermidine, and spermine excretion in urine from patients with blood cancers and solid cancers was significantly increased; information on concentrations of putrescine and spermidine were especially useful for following the clinical efficacy of cancer treatments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of New Transformerless dc-dc Converter With High Voltage Gain

In some industries applications such as fuel cells, we must use a high voltage gain dc-dc converters for increasing voltage, but, the conventional converters cannot provide the high voltage gain with increasing duty cycle and the converters efficiency is limited by the equivalent series resistances. For this reason, in this paper, a single switch transformerless high step-up dc-dc converter wit...

متن کامل

Determination of urinary 3-methoxy-4-hydroxymandelic acid (vanillylmandelic acid) by paper electrophoresis.

called vanillylmandelic acid (VMA), in urine has recently come into use as a confirmatory test for pheochromocytoma (1-6). Armstrong and his associates (1, 2, 7) discovered that this phenolic acid occurred in small amounts in normal human urine and in elevated concentrations in pheochromocytoma. As a result of their observations (1, 2) and especially of those by others in related investigations...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

A stability indicating capillary electrophoresis method for analysis of buserelin

A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 11  شماره 

صفحات  -

تاریخ انتشار 1980