Comparison of Two RapidArc Delivery Strategies in Stereotactic Body Radiotherapy of Peripheral Lung Cancer with Flattening Filter Free Beams

نویسندگان

  • Bao-Tian Huang
  • Jia-Yang Lu
  • Pei-Xian Lin
  • Jian-Zhou Chen
  • Yu Kuang
  • Chuang-Zhen Chen
  • Eric Deutsch
چکیده

PURPOSE To investigate the performance of using partial arc (PA) and full arc with avoidance sectors (FAAS) in stereotactic body radiotherapy (SBRT) of peripheral lung cancer with flattening filter free (FFF) beams. METHODS Eighteen patients with primary (T1 or T2) non-small-cell lung cancer (NSCLC) or lung metastatic were selected for this study. Nine patients with a gross tumor volume (GTV) <= 10 cc were designated as the small tumor group. The other nine patients with a GTV between 10 cc and 44 cc were assigned to the large tumor group. The treatment plans were generated in eighteen patients using PA and FAAS techniques, respectively, and delivered with a Varian TrueBeam Linac. Dosimetry of the target and organs at risk (OARs), monitor unit (MU), out-of-field dose, and delivery time were statistically analyzed. Delta4 and portal dosimetry were employed to evaluate the delivery accuracy. RESULTS For the small tumor group, compared with the PA plans, the FAAS plans significantly achieved a lower MU/fraction, out-of-field dose and a shorter treatment time (p<0.05), but the target dose was slightly higher than that delivered by PA plans (p<0.05). For the large tumor group, the PA plans significantly attained a shorter treatment time (p<0.05), whereas MU/fraction, out-of-field dose and dose to OARs were comparable between the two plans (p>0.05). Furthermore, all plans generated from the eighteen patients achieved a high pass rate in patient-specific quality assurance, with all the gamma indices greater than 97% at the Γ3mm, 3% threshold. CONCLUSION This study suggests that the FAAS technique is more beneficial for the small tumor patients undergoing lung SBRT with FFF beams because of its higher treatment efficiency and MU reduction. However, for the large tumor patients, the PA technique is recommended due to its higher treatment efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A dosimetric and treatment efficiency evaluation of stereotactic body radiation therapy for peripheral lung cancer using flattening filter free beams

To investigate potential dosimetric benefits and treatment efficiency of dynamic conformal arc therapy (DCA), intensity modulated radiation therapy (IMRT), and double partial arcs Rapidarc (RA) techniques in the treatment of early-stage peripheral lung cancer using stereotactic body radiotherapy (SBRT) with flattening filter free (FFF) beams. Twenty early-stage peripheral lung cancer patients w...

متن کامل

Enhancement of the Dose on 12 MV Linac with Free Flattening Filter Mode

Purpose: In the last years, some studies investigated dosimetric benefits of a free flattening filter for the photon mode in the radiotherapy field. This study aims to provide a theoretical study published and analysis of basic dosimetric properties for a Saturne 43 Linac head to implement free flattening filter beams clinically. Material and Methods: Thi...

متن کامل

Stereotactic radiotherapy for lung cancer using a flattening filter free Clinac

The objective of this study was to assess the feasibility of stereotactic radiotherapy for early stage lung cancer using photon beams from a Varian Clinac accelerator operated without a flattening filter. Treatment plans were generated for 10 lung cancer patients with isolated lesions less than 3 cm in diameter. For each patient, two plans were generated, one with and one without the flattening...

متن کامل

Dosimetric Comparison between 6MV Flattened Filter and Flattening Filter Free Photon Beams in the Treatment of Glioblastoma with IMRT Technique: A Treatment Planning Study

Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. Material and Methods: The present study was conducted on 10 patients with GBM previously...

متن کامل

Dosimetric influence of Flattening Filter (FF) and Flattening Filter Free (FFF) 6 and 10 MV photon beams on Volumetric Modulated Arc Therapy (VMAT) planning in case of prostate carcinoma

Background: In the treatment of prostate cancer, radiotherapy is the potential to increase second primary cancers such as bladder and rectal cancers. The reasons for this potential are more monitor units (MUs), therefore a larger total body dose because of leakage radiation, a bigger volume of normal tissue is exposed to lower radiation doses. This study was designed to compare the integral dos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015