The effects of right ventricular apical pacing on ventricular function and dyssynchrony implications for therapy.

نویسندگان

  • Laurens F Tops
  • Martin J Schalij
  • Jeroen J Bax
چکیده

Cardiac pacing is the only effective treatment for patients with sick sinus syndrome and atrioventricular conduction disorders. In cardiac pacing, the endocardial pacing lead is typically positioned at the right ventricular (RV) apex. At the same time, there is increasing indirect evidence, derived from large pacing mode selection trials and observational studies, that conventional RV apical pacing may have detrimental effects on cardiac structure and left ventricular function, which are associated with the development of heart failure. These detrimental effects may be related to the abnormal electrical and mechanical activation pattern of the ventricles (or ventricular dyssynchrony) caused by RV apical pacing. Still, it remains uncertain if the deterioration of left ventricular function as noted in a proportion of patients receiving RV apical pacing is directly related to acutely induced left ventricular dyssynchrony. The upgrade from RV pacing to cardiac resynchronization therapy may partially reverse the deleterious effects of RV pacing. It has even been suggested that selected patients with a conventional pacemaker indication should receive cardiac resynchronization therapy to avoid the deleterious effects. This review will provide a contemporary overview of the available evidence on the detrimental effects of RV apical pacing. Furthermore, the available alternatives for patients with a standard pacemaker indication will be discussed. In particular, the role of cardiac resynchronization therapy and alternative RV pacing sites in these patients will be reviewed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radial left ventricular dyssynchrony by speckle tracking in apical versus non apical right ventricular pacing- evidence of dyssynchrony on medium term follow up.

INTRODUCTION To study effects of various sites of right ventricular pacing lead implantation on left ventricular function by 2-dimensional (2D) speckle tracking for radial strain and LV dyssynchrony. METHODS This was retrospective prospective study. Fifteen patients each with right ventricular (RV) apical (RV apex and apical septum) and non-apical (mid septal and low right ventricular outflow...

متن کامل

Acute left ventricular dysfunction secondary to right ventricular septal pacing in a woman with initial preserved contractility: a case report

INTRODUCTION Right ventricular apical pacing-related heart failure is reported in some patients after long-term pacing. The exact mechanism is not yet clear but may be related to left ventricular dyssynchrony induced by right ventricular apical pacing. Right ventricular septal pacing is thought to deteriorate left ventricular function less frequently because of a more normal left ventricular ac...

متن کامل

The deleterious consequences of right ventricular apical pacing: time to seek alternate site pacing.

BACKGROUND The purpose of this article is to critically review the data accumulated to date from studies evaluating the hemodynamic and clinical effects of right ventricular apical pacing during conventional permanent cardiac pacing. The data from studies comparing the effects of right ventricular apical pacing and alternate site ventricular pacing are also reviewed. METHODS We conducted a ME...

متن کامل

Impact of Right Ventricular Apical Pacing and Its Frequency on Left Atrial Function

BACKGROUND Right ventricular apical (RVA) pacing induces left ventricular (LV) dyssynchrony, increases the risk of persistent atrial fibrillation in the long term. The aim was to investigate the effects of RVA pacing on left atrial (LA) function, which are unknown. METHODS Echocardiographic evaluation including LV dyssynchrony based on conventional Doppler, tissue Doppler imaging and speckle ...

متن کامل

Septal Pacing of Right Ventricle: Has The Last Word Been Said?

The deleterious effects of Right ventricular (RV) pacing on development of ventricular dyssynchrony leading to heart failure, genesis of atrial fibrillation and consequent increased mortality have been repeatedly demonstrated in numerous pacing studies. Trials with dual chamber pacemakers and defibrillators did not succeed in negating these effects, raising the question if it was RV pacing per ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 54 9  شماره 

صفحات  -

تاریخ انتشار 2009