Rhythm Diagnosis and Management Aided by Stored Electrogram Analysis
نویسندگان
چکیده
Background. This report describes the value of stored ventricular electrogram analysis in the diagnosis and management of patients experiencing minimal or no symptoms before implantable cardioverterdefibrillator (ICD) therapy. Methods and Results. The study population included 48 patients who received the Cadence Tiered Therapy Defibrillator System, an investigational third-generation ICD with ventricular electrogram storage capabilities. Criteria for arrhythmia diagnosis were based on analysis of the electrogram rate, RR interval variability, and morphology. Twenty-nine of the 48 patients (60%o) experienced at least one episode of antitachycardia pacing or shock (one shock or more in 25 of 29 patients) that was preceded by minimal or no symptoms during a mean follow-up of 15.1±7.8 months. There were 194 tachycardia episodes registered by the device, including 101 for which ventricular electrograms were stored and available for analysis. Of the 101 stored electrograms, 74 were classified as ventricular tachycardia (VT), 24 as non-VT rhythms (atrial fibrillation, 13; supraventricular tachycardia, six; rate-sensing lead disruption, four, T wave oversensing, one), and only three as indeterminate rhythms. Based on the electrogram analysis, changes in tachycardia detection criteria and/or antiarrhythmic drug regimens were implemented and were associated with a reduction in the number of device responses for non-VT rhythms from 24 during the initial study period to three during 11.0±7.2 months of additional follow-up. Conclusions. ICD responses in the absence ofsymptoms are relatively common in third-generation devices with antitachycardia pacing capabilities. Despite potential limitations such as the effect of bundle branch block on the electrogram morphology during supraventricular tachycardia, the availability of electrogram storage capabilities allowed a presumptive diagnosis of the events precipitating asymptomatic device responses. Device reprogramming based on analysis of stored electrograms was associated with a dramatic reduction in the incidence of ICD responses for non-VT rhythms. (Circulation 1993;87:1897-1906)
منابع مشابه
Implantable cardioverter-defibrillator therapy in the absence of significant symptoms. Rhythm diagnosis and management aided by stored electrogram analysis.
BACKGROUND This report describes the value of stored ventricular electrogram analysis in the diagnosis and management of patients experiencing minimal or no symptoms before implantable cardioverter-defibrillator (ICD) therapy. METHODS AND RESULTS The study population included 48 patients who received the Cadence Tiered Therapy Defibrillator System, an investigational third-generation ICD with...
متن کاملWhat Can We Learn From the RR Intervals Stored in ICDs?
By recording electrocardiograms (ECG) over an extended period of time, conventional Holter monitors can detect heart rhythm abnormalities that are not continuously present, or can help determine if rhythm disturbances are associated with symptoms. Two common approaches have been widely used for Holter ECG analysis: one is based on ECG waveform analysis and the other on RR interval data analysis...
متن کاملIdentification of ventricular tachycardia using intracardiac electrograms: a comparison of unipolar versus bipolar waveform analysis.
Implantable antitachycardia devices suffer a high false-positive rate of delivery of therapy because current detection schemes based upon ventricular rate and rate variations are excessively sensitive at the cost of specificity. Several methods have been proposed for providing complementary information derived from morphologic analysis of intraventricular electrograms in order to increase speci...
متن کاملAbsence of junctional rhythm during successful slow-pathway ablation in patients with atrioventricular nodal reentrant tachycardia.
BACKGROUND The presence of junctional rhythm has been considered to be a sensitive marker of successful slow-pathway ablation. However, in rare cases, junctional rhythm was absent despite multiple radiofrequency applications delivered over a large area in the Koch's triangle, and successful ablation was achieved in the absence of a junctional rhythm. METHODS AND RESULTS This study included 35...
متن کاملComputerize classification of Benign and malignant thyroid nodules by ultrasound imaging
Introduction: Early detection and treatment of thyroid nodules increase the cure rate and provide optimal treatment. Ultrasound is the chosen imaging technique for assessment of thyroid nodules. Confirmation of the diagnosis usually demands repeated fine needle aspiration biopsy (FNAB). So, current management, has morbidity and non zero mortality. The goal of the present study ...