Temporary epicardial left ventricular and biventricular pacing improves cardiac output after cardiopulmonary bypass

نویسندگان

  • Jose B García-Bengochea
  • Angel L Fernández
  • Daniel Sánchez Calvelo
  • Julian Alvarez Escudero
  • Francisco Gude
  • José R González Juanatey
چکیده

BACKGROUND To evaluate, with different pacing modes, acute changes in left ventricular systolic function, obtained by continuous cardiac output thermodilution in various subsets of patients undergoing cardiopulmonary bypass surgery. Increments of mean arterial pressure and cardiac output were considered the end point. METHODS Fifty cases electively submitted to cardiac surgery were analyzed. Isolated valve surgery 62%, coronary revascularization 30% and 8% mixed disease. Left ventricular ejection fraction was preserved in 50%,36% had moderate depression,(EF 36%-50%) whereas 14% had severe depression (EF < 35%). Left bundle branch block occurred in 18%. Preoperatively 84% were in sinus rhythm and 16% in atrial fibrillation. The different subgroups were analyzed for comparisons. Right atrial-right ventricular and right atrial-left ventricular pacing were employed in sinus rhytm. Biventricular pacing was also used in atrial fibrillation. RESULTS Right atrium-right ventricular pacing, decreased significantly mean arterial pressure and cardiac output (2.3%) in the overall population and in the subgroups studied. Right atrium-left ventricle, increased mean arterial pressure and cardiac output in 79% of patients and yielded cardiac output increments of 7.5% (0.40 l/m) in the low ejection fraction subgroup and 7.3% (0.43 l/m) in the left bundle branch block subset. In atrial fibrillation patients, left ventricular and biventricular pacing produced a significant increase in cardiac output 8.5% (0.39 l/min) and 11.6% (0.53 l/min) respectively. The dP/dt max increased significantly with both modes (p = 0.021,p = 0.028). CONCLUSION Right atrial-right ventricular pacing generated adverse hemodynamic effects. Right atrium-left ventricular pacing produced significant CO improvement particularly in cases with depressed ventricular function and left bundle branch block. The greatest increments were observed with left ventricular or biventricular pacing in atrial fibrillation with depressed ejection fraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temporary left ventricular pacing improves haemodynamic performance in patients requiring epicardial pacing post cardiac surgery.

OBJECTIVE In the 1990s, sequential atrio-ventricular pacing demonstrated haemodynamic benefit relative to right ventricular pacing in patients with sinus rhythm requiring pacing post cardiopulmonary bypass. The benefit of biventricular pacing has been demonstrated in non-surgical patients with severe left ventricular dysfunction. It was hypothesised that left ventricular pacing would increase c...

متن کامل

Biventricular pacing in conjunction with epicardial atrial pacing adversely affects timing of intra-aortic balloon pump.

A case of accidental triggering of an intra-aortic balloon pump during systole is presented. The patient had a cardiac resynchronization therapy device in place preoperatively for heart failure. A temporary epicardial atrial pacing wire was used during separation from cardiopulmonary bypass for rate control. An intra-aortic balloon pump was necessary for separation from bypass. Although the pac...

متن کامل

The effect of biventricular pacing after coronary artery bypass grafting: a prospective randomized trial of different pacing modes in patients with reduced left ventricular function.

OBJECTIVES Biventricular pacing acutely improves left ventricular function in patients with heart failure and left ventricular dyssynchrony. Pressure-volume loop analysis has shown acute perioperative hemodynamic benefits of biventricular pacing immediately after weaning from cardiopulmonary bypass in patients undergoing coronary artery bypass grafting, but whether these effects can be maintain...

متن کامل

Acute biventricular pacing after cardiac surgery has no influence on regional and global left ventricular systolic function.

BACKGROUND Cardiac resynchronization therapy has been shown to improve systolic function in patients with advanced chronic heart failure and electromechanical delay (QRS width > 120 ms). However, the effect of acute biventricular (BiV) pacing on perioperative haemodynamic changes is not well defined. In the present study, acute changes in regional left ventricular (LV) systolic function determi...

متن کامل

Aortic bleeding one week after removal of an intraoperative epicardial temporary pacing wire.

A 56-year-old man had left nephrectomy and resection of a cavoatrial tumor thrombus under a cardiopulmonary bypass assist for left renal cell carcinoma. An intraoperative bipolar temporary epicardial atrial pacing wire was removed on postoperative day 8. The patient collapsed on postoperative day 15. Emergent transthoracic echocardiography and computed tomography scanning with contrast media de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012