Comparison of sonography and computed tomography in the study of orbital space-occupying lesions.

نویسندگان

  • O Berges
  • J Vignaud
  • M L Aubin
چکیده

Seventy cases of space-occupying lesions in the eyeball and 140 extraocular masses in the orbit were explored by both sonography and compute tomography (CT). The merits of each method were demonstrated relative to defining the location, extension, and nature of the lesion. In adults with ocular masses, sonography is usually sufficient. For retinoblastoma, CT is usually necessary to rule out an extraocular extension. When an orbital process is involved, greater diagnostic accuracy can be achieved if the two methods are combined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3-D computed tomography reconstruction: another tool to teach anatomy in the veterinary colleges

This letter underpins the use of three-dimensional computed tomography (3D-CT) reconstruction as an aid to teach veterinary anatomy. Cases were presented to students in order to observe normal and clinically abnormal patients. The images provided excellent details of relevant structures and could serve as a tool for teaching anatomy. Many sources describe different options to enhance anatomical...

متن کامل

Renal imaging: a comparison of radionuclide, ultrasound, and computed tomographic scanning in investigation of renal space-occupying lesions.

Two studies were carried out in which 27 and 23 patients respectively with renal space-occupying lesions were assessed by different techniques and the results compared. Instead of proceeding to renal arteriography after the lesion had been found on urography, radionuclide and ultrasound scanning were used in the first study to clarify the nature of the lesions, while in the second study compute...

متن کامل

The Accuracy of Ultrasonography in Compared with Computed Tomography in Detection of Anterior Mediastinal Neoplasms

Abstract Background The aim of this study was to evaluate sensitivity and specificity of mediastinal sonography, and compared with CT, in detection of anterior mediastinal neoplasms. Materials and Methods The sonography with convex probes (5.0 and 7.5 MHz) was done prospectively for 34 patients (from 2 to 25 years old) with mediastinal mass. The results were compared with the results of ...

متن کامل

Prevalence of Idiopathic Osteosclerosis on Cone Beam Computed Tomography Images

Objectives: This study was performed to investigate the prevalence of idiopathic osteosclerosis on cone beam computed tomography (CBCT) images of patients. Methods: In this descriptive, cross-sectional study, 240 CBCT scans of patients (125 women, 115 men) referred to a private oral and maxillofacial radiology clinic in Tehran in 2013 were selected and evaluated. Presence of idiopathic osteosc...

متن کامل

Comparison of the Results of Fine Needle Aspiration Biopsy Specimens and Permanent Histopathologic Preparation in Orbital Mass Lesions

Background and Objectives: We aimed at evaluating the efficacy of fine needle aspiration biopsy (FNA) in comparison with histopathology and demonstrating whether cytological study could be a proper diagnostic tool in orbital mass lesions. Materials and Methods: In a cross sectional study during 36 months, patients referred to our ophthalmologic center affiliated to Tehran University of Medical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 5 3  شماره 

صفحات  -

تاریخ انتشار 1984