Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS): comparison of different internal standardization methods using laser-induced plasma (LIP) emission and LA-ICP-MS signals.
نویسندگان
چکیده
The source of signal variations that governs the analytical performance of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was investigated in this study. In order to specify the source of signal variations of LA-ICP-MS, laser-induced plasma (LIP) Fe emission, LA-ICP-MS Fe+ and LA-ICP-MS Ni+ signals were used as internal standards for the determination of trace elements in low-alloy steel certified reference materials (BS 50D and JSS 1005-1008). Fe 1373.5 nm emission signals from LIP were measured, while trace element LA-ICP-MS signals were collected. After that, the LIP emission signals, LA-ICP-MS Fe+ and LA-ICP-MS Ni+ signals were used as internal standards, and the analytical performance was evaluated by the RSDs and the correlation coefficients (r) of the calibration curves. The improvement factors were dependent on the internal standardization methods. Analytical precisions (RSDs) of trace element LA-ICP-MS signals were improved by factors of 1.5-3.3 using LIP Fe emission signals as an internal standard. The improvement factors of 2.5 - 5.9 and 4.1 - 17 were obtained by using LA-ICP-MS Fe+ and LA-ICP-MS Ni+ signals as internal standards, respectively. Better correlation coefficients (r) were also obtained using the LA-ICP-MS signal compensation (0.9985 by LA-ICP-MS Fe+ and 0.9996 by LA-ICP-MS Ni+) rather than the LIP Fe emission compensation (0.9932). In this paper we compare and discuss the analytical performance achieved by LA-ICP-MS using LIP Fe emission, LA-ICP-MS Fe+ and LA-ICP-MS Ni+ signals as internal standards.
منابع مشابه
Laser Ablation (LA)-ICP-MS for Production Control of Nickel Alloys Application
Nickel alloys are used extensively across a wide range of industries, often in components which are required to perform critical functions under arduous operating conditions. As a result, the physical, chemical, and mechanical properties of such alloys must be well understood and the levels of trace metal contaminants, which may have a profound effect on these properties, must be strictly contr...
متن کاملAnalysis of trace metals in comparison of laser-induced breakdown spectroscopy with LA-ICP-MS
Laser-induced breakdown spectroscopy (LIBS) and LA-ICP-MS (laser ablation inductively coupled plasma mass-spectrometry) were used for the detection of trace metals in a solid matrix consisting of KBr and two oxides. The results of both methods were compared to investigate the strengths and weaknesses of both methods. Most difficulties for quantification of LIBS data are related to matrix effect...
متن کاملEnhancing Laser Ablation ICP-MS using Sector Field Technology
• Multi-Element Analysis Introduction Laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS) has developed over recent years to become a sophisticated tool for the multielemental and isotope ratio analysis of solid samples. Besides a true multi-elemental capability, independent of matrix, the major requirements for most geological laser applications in ICP-MS are the highest se...
متن کاملInter-element fractionation and correction in laser ablation inductively coupled plasma mass spectrometry
Inter-element fractionation in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) analysis is one of the major challenges for using the technique for in situ trace element determination and isotopic ratio measurement of geological, environmental and biological solid samples. Attempts have been made to reduce inter-element fractionation in LA-ICP-MS analysis. However, this f...
متن کاملA new laser ablation system for quantitative analysis of solid samples with ICP-MS.
The laser ablation (LA) method is an effective technique for quantitative analysis. In the present work, a new LA system was developed for the high-sensitivity analysis of metal materials using inductively coupled plasma mass spectrometry (ICP-MS). This system consists of a high-frequency Q-switched laser and 2 scanning mirrors for scanning the ablation spot in an adequately large area of the s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 18 10 شماره
صفحات -
تاریخ انتشار 2002