OBJECTIVE To assess the feasibility of single-breath-hold three-dimensional cine b-SSFP (balanced steady-state free precession gradient echo) sequence (3D-cine), accelerated with k-t BLAST (broad-use linear acquisition speed-up technique), compared with multiple-breath-hold 2D cine b-SSFP (2D-cine) sequence for assessment of left ventricular (LV) function. METHODS Imaging was performed using 1.5-T MRI (Achieva, Philips, The Netherlands) in 46 patients with different cardiac diseases. Global functional parameters, LV mass, imaging time and reporting time were evaluated and compared in each patient. RESULTS Functional parameters and mass were significantly different in the two sequences [3D end-diastolic volume (EDV) = 129 ± 44 ml vs 2D EDV = 134 ± 49 ml; 3D end-systolic volume (ESV) = 77 ± 44 ml vs 2D ESV = 73 ± 50 ml; 3D ejection fraction (EF) = 43 ± 15% vs 2D EF = 48 ± 15%; p < 0.05], although an excellent correlation was found for LV EF (r = 0.99). Bland-Altman analysis showed small confidence intervals with no interactions on volumes (EF limits of agreement = 2.7; 7.6; mean bias 5%). Imaging time was significantly lower for 3D-cine sequence (18 ± 1 s vs 95 ± 23 s; p < 0.05), although reporting time was significantly longer for the 3D-cine sequence (29 ± 7 min vs 8 ± 3 min; p < 0.05). CONCLUSIONS A 3D-cine sequence can be advocated as an alternative to 2D-cine sequence for LV EF assessment in patients for whom shorter imaging time is desirable.
منابع مشابه
Fast 3D cine steady-state free precession imaging with sensitivity encoding for assessment of left ventricular function in a single breath-hold.
OBJECTIVE This study compares single breath-hold 3D cine steady-state free precession (SSFP) MRI using sensitivity encoding (SENSE) with standard 2D cine SSFP imaging in the quantitative evaluation of global left ventricular (LV) function. MATERIALS AND METHODS The LV function of 22 healthy volunteers and 15 patients was evaluated using a standard 2D SSFP sequence and a 3D SSFP sequence with ...
متن کاملSingle breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent
BACKGROUND Cardiovascular magnetic resonance (CMR) is the current gold standard for the assessment of left ventricular (LV) function. Repeated breath-holds are needed for standard multi-slice 2D cine steady-state free precession sequences (M2D-SSFP). Accelerated single breath-hold techniques suffer from low contrast between blood pool and myocardium. In this study an intravascular contrast agen...
متن کاملEvaluation of left ventricular volumes and ejection fraction using fast steady-state cine MR imaging: comparison with left ventricular angiography.
Previous studies demonstrated that magnetic resonance (MR) imaging consistently underestimated angiographic measurements of left ventricular (LV) volumes. The purpose of this study was to determine whether MR imaging with steady-state free precession acquisition (SSFP) can provide improved accuracy and reproducibility in measuring cardiac function in comparison with fast spoiled gradient echo c...
متن کاملReal-time magnetic resonance cine imaging with sparse sampling and iterative reconstruction for ventricular measures: comparison with gold-standard segmented steady-state free precession
Background Segmented cine imaging with a steady-state free precession sequence (CINE-SSFP) is currently the gold standard technique for measuring ventricular volumes and mass. It requires multiple breath-holds to cover the entire ventricles, thus being prone to misalignment of consecutive slices, time consuming and dependent on breath-hold (BH) capability. Real-time cine avoids those limitation...
متن کاملThe accuracy and effectiveness of self-gating signals in free-breathing 3D cardiac cine MRI
Background Conventional cardiac cine magnetic resonance imaging (MRI) is typically based on the segmented data acquired by breath-hold 2D balanced steady-state free procession (SSFP) pulse sequence [1]. However, the slice misregistration caused by the variation of breath holding positions could compromise the effectiveness of 2D SSFP, and breath-hold makes it difficult for pediatric patients or...