Noninvasive evaluation of coronary reperfusion by transthoracic Doppler echocardiography in patients with anterior acute myocardial infarction before coronary intervention.

نویسندگان

  • Souki Lee
  • Yutaka Otsuji
  • Shinichi Minagoe
  • Shuichi Hamasaki
  • Koichi Toyonaga
  • Midori Negishi
  • Masanori Tsurugida
  • Hitoshi Toda
  • Chuwa Tei
چکیده

BACKGROUND Transthoracic Doppler echocardiography (TTDE) enables evaluation of distal left anterior descending coronary artery (LAD) flow. The purpose of this study was to test whether TTDE can differentiate coronary reperfusion with Thrombolysis in Myocardial Infarction (TIMI) grade 3 from TIMI grade < or =2 in patients with anterior acute myocardial infarction (AMI). METHODS AND RESULTS In 46 consecutive patients with a first anterior AMI in the acute phase before emergent coronary intervention, the presence of antegrade distal LAD flow and its diastolic peak velocity were evaluated by color and pulsed TTDE and compared with TIMI grades by subsequent coronary angiography performed 29+/-12 minutes later. Nineteen patients had TIMI 0 reperfusion, 4 had TIMI 1, 10 had TIMI 2, and 13 had TIMI 3. Visual antegrade distal LAD flow was present in 22 of the 46 patients. TIMI 2 and 3 reperfusions were both generally visualized by color TTDE. However, peak distal LAD flow velocity by pulsed TTDE was significantly greater in patients with TIMI 3 compared with those with TIMI 2 (40+/-10 vs 20+/-6 cm/s, P<0.0001). The diagnosis of TIMI 3 based on diastolic peak distal LAD flow velocity > or =25 cm/s by TTDE had a sensitivity, specificity, and accuracy of 77%, 94%, and 89%, respectively. CONCLUSIONS TTDE enables noninvasive differentiation of TIMI 3 from TIMI < or =2 coronary reperfusion in patients with AMI in the acute phase before emergent coronary intervention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CARDIOVASCULAR MEDICINE Coronary flow velocity analysis during short term follow up after coronary reperfusion: use of transthoracic Doppler echocardiography to predict regional wall motion recovery in patients with acute myocardial infarction

Background: A recent study using a Doppler guide wire showed that coronary flow velocity measurements immediately after coronary reperfusion were useful in predicting recovery of regional left ventricular function. The value of coronary flow velocity analyses during follow up after reperfusion has not been established in the clinical setting. Objective: To evaluate coronary flow velocity measur...

متن کامل

Coronary flow velocity analysis during short term follow up after coronary reperfusion: use of transthoracic Doppler echocardiography to predict regional wall motion recovery in patients with acute myocardial infarction.

BACKGROUND A recent study using a Doppler guide wire showed that coronary flow velocity measurements immediately after coronary reperfusion were useful in predicting recovery of regional left ventricular function. The value of coronary flow velocity analyses during follow up after reperfusion has not been established in the clinical setting. OBJECTIVE To evaluate coronary flow velocity measur...

متن کامل

Evaluation of ejection fraction in patients with acute myocardial infarction undergoing percutaneous coronary intervention

Introduction: Percutaneous coronary intervention (PCI) is a reperfusion strategy to increase life expectancy and ejection fraction (EF) in ST-segment elevation myocardial infarction (STEMI) patients. We investigated the effect of location, severity, type of lesion, number and type of vessel involved and time of angioplasty on the increase in EF in STEMI patients undergoing primary PCI (P-PCI) a...

متن کامل

Assessing myocardial perfusion with the transthoracic Doppler technique in patients with reperfused anterior myocardial infarction: comparison with angiographic, enzymatic and electrocardiographic indices.

AIMS Doppler guidewire studies demonstrated that the no-reflow phenomenon in acute myocardial infarction is associated with characteristic coronary blood flow pattern. We investigated the potential of coronary flow measurement with transthoracic Doppler technique to detect the no-flow in the patients with reperfused infarction, and compared it to that of other modalities. METHODS AND RESULTS ...

متن کامل

The slippery slope.

The achievement of adequate and prompt myocardial reperfusion in acute myocardial infarction (AMI) is the most important determinant of recovery of ventricular function at follow-up. This explains the great attention given to the so-called no-reflow phenomenon, which is associated with extensive myocardial damage and a high prevalence of future cardiac events after AMI. The no-reflow phenomenon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 108 22  شماره 

صفحات  -

تاریخ انتشار 2003