Prostate DCE-MRI with a 16-Channel Surface Array and Endorectal Coil Using Slice Oversampling and SENSE to Minimize Blood Inflow Effect
نویسندگان
چکیده
Introduction: The reliability of pharmacokinetic (PK) parameters derived from DCE-MRI using approaches such as the Generalized Kinetic Model (GKM) depends on the accuracy of the measured arterial input function (AIF). For prostate studies, the best AIF locations are the femoral arteries which are susceptible to a large inflow effect which shortens the apparent blood T1 and results in inconsistent contrast agent concentration. One way to solve this problem is using a prepolarization slab applied superior to the imaging volume, but the additional pulse increases SAR. In this work, we achieve the same result by exciting a thicker volume and using slice oversampling with SENSE to maintain the same data size and temporal resolution.
منابع مشابه
Detection of local recurrent prostate cancer after radical prostatectomy in terms of salvage radiotherapy using dynamic contrast enhanced-MRI without endorectal coil
PURPOSE To evaluate the value of dynamic contrast enhanced Magnetic Resonance Imaging (DCE-MRI) without endorectal coil (EC) in the detection of local recurrent prostate cancer (PC) after radical prostatectomy (RP). MATERIAL AND METHODS Thirty-three patients with recurrent PC underwent DCE-MRI without EC before salvage radiotherapy (RT). At median 15 (mean 16±4.9, range 12-27) months after co...
متن کاملPhased-array MRI of canine prostate using endorectal and endourethral coils.
A four-channel phased array consisting of one surface coil, two endorectal coils, and one flexible endourethral loop coil was designed for MRI of the canine prostate. The endorectal coils provide high signal in the posterior region of the prostate, while the endourethral and surface coils are sensitive to the central and anterior regions of the prostate. Gel phantom experiments indicate that th...
متن کاملWhole Prostate Volume and Shape Changes with the Use of an Inflatable and Flexible Endorectal Coil
Purpose. To determine to what extent an inflatable endorectal coil (ERC) affects whole prostate (WP) volume and shape during prostate MRI. Materials and Methods. 79 consecutive patients underwent T2W MRI at 3T first with a 6-channel surface coil and then with the combination of a 16-channel surface coil and ERC in the same imaging session. WP volume was assessed by manually contouring the prost...
متن کاملComparison of Pelvic Phased-Array versus Endorectal Coil Magnetic Resonance Imaging at 3 Tesla for Local Staging of Prostate Cancer
PURPOSE Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Tesla for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Tesla MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil ...
متن کاملMR Spectroscopic Imaging of Peripheral Zone in Prostate Cancer Using a 3T MRI Scanner: Endorectal versus External Phased Array Coils
Magnetic resonance spectroscopic imaging (MRSI) detects alterations in major prostate metabolites, such as citrate (Cit), creatine (Cr), and choline (Ch). We evaluated the sensitivity and accuracy of three-dimensional MRSI of prostate using an endorectal compared to an external phased array "receive" coil on a 3T MRI scanner. Eighteen patients with prostate cancer (PCa) who underwent endorectal...
متن کامل