Correlation between contrast sensitivity and higher-order aberration based on pupil diameter after cataract surgery
نویسندگان
چکیده
BACKGROUND The purpose of this study was to evaluate the correlation between contrast sensitivity and calculated higher-order aberrations based on individual natural pupil diameter after cataract surgery. METHODS This prospective study included 120 eyes from 92 patients who were randomized to receive one of four lenses, including three aspheric lenses (Acrysof SN60WF, Tecnis ZA9000, and Hoya Py60AD) and one spherical lens (Acrysof SN60AT). Contrast sensitivity, higher-order aberrations of the whole eye, and pupil diameter under photopic and mesopic conditions were measured 1 month postoperatively. Higher-order aberrations were decomposed into Zernike coefficients, calculated according to individual pupil diameter. The correlation between higher-order aberrations and contrast sensitivity was evaluated. RESULTS There were no significant differences in contrast sensitivity function between the four types of lenses under photopic conditions. However, the contrast sensitivity function and area under log contrast sensitivity function in the aspheric lenses were significantly better than in the spherical lens under mesopic conditions. Under mesopic conditions, spherical aberration in eyes with aspheric lenses was significantly lower than in eyes with spherical lenses (P < 0.05). Under photopic conditions, coma aberration had a significant negative correlation with contrast sensitivity at 12 cycles/degree. Under mesopic conditions, spherical aberration had a significant negative correlation with contrast sensitivity at 3, 6, and 12 cycles/degree with glare, and with contrast sensitivity at 6 and 18 cycles/degree without glare. CONCLUSION In terms of influence on visual function, coma aberration may be more significant under photopic conditions and spherical aberration under mesopic conditions.
منابع مشابه
Influence of pupil diameter on the relation between ocular higher-order aberration and contrast sensitivity after laser in situ keratomileusis.
PURPOSE To investigate the influence of pupil diameter on the relation between induced changes in ocular higher-order wavefront aberrations and changes in contrast sensitivity by conventional laser in situ keratomileusis (LASIK) for myopia. METHODS In 215 eyes of 117 patients (age, 33.2 +/- 8.3 years) undergoing LASIK for myopia of -1.25 to -13.5 D (-5.28 +/- 2.55 D), ocular wavefront aberrat...
متن کاملEffect of cataract surgery incision location and intraocular lens type on ocular aberrations.
PURPOSE To determine whether Hartmann-Shack wavefront sensing detects differences in optical performance in vivo between poly(methyl methacrylate) (PMMA) and foldable acrylic intraocular lenses (IOLs) and between clear corneal and scleral tunnel incisions and whether optical differences are manifested as differences in visual performance. SETTING Department of Optometry, University of Bradfor...
متن کاملWavefront analysis in eyes with nuclear or cortical cataract.
PURPOSE To compare the higher-order aberrations of the oculus (whole eye) and cornea in eyes with mild cortical or nuclear cataract and to estimate the effect of ocular higher-order aberrations on the loss of contrast sensitivity using wavefront analysis. DESIGN Observational case series. METHODS Six eyes of four patients with mild nuclear cataract, 18 eyes of 14 patients with mild cortical...
متن کاملQuality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation: effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision.
PURPOSE To compare ocular performance and quality of vision in pseudophakic eyes with an aspherical intraocular lens (IOL) or a conventional spherical IOL. SETTING Bretonneau University Hospital, Tours, France. METHODS Twenty patients (40 eyes) were randomly divided in 2 equal groups to bilaterally receive the aspherical Tecnis Z9000 IOL (AMO) or the spherical CeeOn Edge 911 IOL (AMO). Cont...
متن کاملWavefront aberrations in eyes with Acrysof monofocal intraocular lenses.
PURPOSE To characterize and measure the ocular aberrations in eyes implanted with monofocal intraocular lenses (IOLs) and to study any correlation between postoperative aberrations and surgical factors. METHODS A Tscherning aberroscope was used to measure the wavefront aberrations of 62 eyes that had undergone phacoemulsification with the implantation of foldable monofocal Acrysof MA60BM IOLs...
متن کامل