Performance and comparison of gold-based neutron flux monitors

نویسندگان

  • Georg Steinhauser
  • Stefan Merz
  • Franziska Stadlbauer
  • Peter Kregsamer
  • Christina Streli
  • Mario Villa
چکیده

In two test series, liquid and solid gold-based neutron flux monitor materials were investigated with respect to the effects of neutron absorbers such as chlorine, scattering effects, and the dependence of the enhanced activation caused by the epithermal resonance integral. The liquid monitors were prepared from aqueous solutions of tetraamminegold(III) nitrate and tetrachloroauric(III) acid. The presence of chlorine-35 partly suppresses the activation of gold-197; this effect depends not only on the concentration of the absorber but also on the state of the neutron flux density monitor. Aqueous samples show greater relative losses than solid monitors. Neutron scattering occurs in hydrogen-rich sample matrices which is shown by the fact that cadmium-shielded aqueous samples show an over proportional activation. Hence, fast neutrons must be moderated to the epithermal energies covered by the resonance integral, which is characterized by much greater cross sections for the capture of neutrons. The insight of this study with respect to neutron scattering in hydrogen-rich matrices must be taken into account also for neutron activation analysis; sample and standard must have a similar matrix with respect to its neutron scattering properties, otherwise the effect of increased activation as well as of enhanced selfshielding are underestimated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of the flux of a neutron radioisotope source through gold activation method

Introduction: In recent years, the use of neutrons has increased in various fields such as medicine and industry. One of the important applications of neutrons is in medical research. Neutrons have greater linear energy transfer than gamma rays and are considered more dangerous radiation. Hence, the detection and determination of neutron dose is a very important and vital issu...

متن کامل

Designing an Am-Be miniature neutron source

Background: Miniature neutron sources with high neutron flux have abundant applications in medicine, industry and researches. The most important general characteristic of miniature neutron sources is their diameter which is 3mm in average. In this research, we have surveyed and designed an Am-Be miniature neutron source fabrication. Materials and Methods: This investigation resulted in creation...

متن کامل

Re-characterization of irradiation facilities for k0-NAA at RPI after conversion to LEU fuel and re-arrangement of core configuration

The 1MW pool-type Portuguese research reactor (RPI) was converted from using highly enriched uranium (HEU) to using low enriched uranium (LEU) fuel in September 2007. Although the new LEU core has the same number of fuel assemblies as the first HEU core, it has three assemblies less than the last HEU core and also has a different arrangement of the beryllium reflectors. Therefore, the primary i...

متن کامل

Simulation of the BNCT of Brain Tumors Using MCNP Code: Beam Designing and Dose Evaluation

Introduction BNCT is an effective method to destroy brain tumoral cells while sparing the healthy tissues. The recommended flux for epithermal neutrons is 109 n/cm2s, which has the most effectiveness on deep-seated tumors. In this paper, it is indicated that using D-T neutron source and optimizing of Beam Shaping Assembly (BSA) leads to treating brain tumors in a reasonable time where all IAEA ...

متن کامل

Passive neutron area monitor with CR39

Background: In high-intensity, mixed and pulsed neutron fields the use of spectrometers or area monitors with active detectors is useless in these conditions neutron measuring devices must have a passive detector. Here a passive neutron area monitor with CR39 track detector was designed and the response was calculated. Materials and Methods: The response of a passive neutron area monitor with C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012