Determination of High Zn and Pb Concentrations in Polluted Soils Using Energy-Dispersive X-ray Fluorescence Spectrometry

نویسندگان

  • R. Sitko
  • B. Zawisza
  • J. Jurczyk
  • F. Buhl
  • U. Zielonka
چکیده

A method of determination of high Zn and Pb concentrations by means of EDXRF (energy-dispersive X-ray fluorescence spectrometry) is presented. Zn and Pb concentration in soil samples from contaminated areas ranged within a limit of Zn: 800–2000ppm and Pb: 200–600ppm. Soil analysis was conducted directly after the samples had been dried and powdered, as well as in situ in polluted areas. Due to the absence of the certificate reference materials for soils with such high Zn and Pb concentrations, samples of soil with the Pb and Zn amounts determined using the AAS method were used to perform calibration. The obtained detection limits are 30ppm and 19ppm for Zn and Pb, respectively. Because of the high analytes concentration and material heterogeneity, the repeatability of the results was examined according to the sample holder’s various positions in EDXRF analyzer; repeatability the of the results while putting into the sample holder and out of it, together with the repeatability of making the calibration. The results obtained using the EDXRF method were compared to these obtained using AAS and wavelength-dispersive X-ray fluorescence spectrometry (WDXRF).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of sediment samples for some trace and major metals from Okaba coal mine in Kogi State, Nigeria by energy-dispersive x-ray fluorescence spectrometry: Effect of seasonal variations on the concentrations of these metals

Coal sediment samples from Okaba coal mine in Kogi State, Nigeria, were subjected to analysis for some metallic and non-metallic compositions. Of 35 elements determined by energy-dispersive X-ray fluorescence spectrometry, a number of anomalously high levels were recorded. Elements determined are Al, Si, P, S, K, Ca, Ti, Cr, Mn, V, Fe, Ni, Cu, Zn, Rb, Zr, Ru, Ba, Sr, Y, Se, Os, Bi, Sb, Pb, Mg, ...

متن کامل

Contamination Characteristics and Assessment of Manganese, Zinc, Chrome, Lead, Copper and Nickel in Bus Station Dusts of Xifeng, Northwest China

The objective of this study was to investigate the concentration and spatial distribution patterns of six potentially toxic heavy metal elements (Mn, Zn, Cr, Pb, Cu and Ni) in bus station dusts in the Xifeng district of Gansu province, NW China. The contents were analyzed for Mn, Zn, Cr, Pb, Cu and Ni by using S8 TIGER Brochures wavelength dispersive X-ray fluorescence spectrometry. Geoaccumula...

متن کامل

Quantitative analysis of heavy metals in automotive brake linings: a comparison between wet-chemistry based analysis and in-situ screening with a handheld X-ray fluorescence spectrometer.

Two extraction procedures for ecologically relevant elements present in automotive brake linings (Sb, Bi, Pb, Cd, Cr (total), Co, Cu, Mo, Ni, Sr, V, Zn, Sn) were developed and validated, applying a high pressure asher (HPA-S) and microwave extraction, respectively. Both of these methods allowed for the quantitative analysis of the extracted elements by inductively coupled plasma optical emissio...

متن کامل

Determination of Cr, Zn, As and Pb in Soil by X-Ray Fluorescence Spectrometry Based on a Partial Least Square Regression Model

Soil samples were collected from five provinces over China, including Beijing, Xinjiang, Heilongjiang, Yunnan, and Jiangsu. Heavy metal Cr, Zn, Pb and As in soils were analyzed by a portable X-ray fluorescence spectrometry (XRF). For predicating metal concentration in soils, a partial least square regression model (PLSR) was established. After cross-calibration, the correlation coefficients for...

متن کامل

Simultaneous determination of trace elements in serum by energy-dispersive x-ray fluorescence spectrometry.

Energy-dispersive x-ray fluorescence is applied in the analysis of human serum to determine the concentrations of several elements simultaneously with minimal manipulation of the sample. The analytical procedure has been developed with standard sera, and standardization, detection limits, and reproducibility have been established. A 50-microL sample of diluted serum, to which an internal standa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006