Baroreceptor-mediated compensation for hemodynamic effects of positive end-expiratory pressure.

نویسندگان

  • S S Blevins
  • M J Connolly
  • D E Carlson
چکیده

The roles of the carotid arterial baroreceptor reflex and of vagally mediated mechanisms during positive end-expiratory pressure (PEEP) were determined in pentobarbital-anesthetized dogs with isolated carotid sinuses. Spontaneously breathing dogs were placed on PEEP (5-10 cmH2O) with the carotid sinus pressure set to the systemic arterial pressure (with feedback) or to a constant pressure (no feedback). Right atrial volume was measured with a conductance catheter. With carotid baroreceptor feedback before bilateral cervical vagotomy, total peripheral resistance increased (P < 0.01) and mean arterial pressure decreased (-9.8 +/- 4.3 mmHg) in response to PEEP. With no feedback after vagotomy, mean arterial pressure decreased to a greater extent (-45 +/- 6 mmHg, P < 0.01), and total peripheral resistance decreased (P < 0.05) in response to PEEP. In contrast, cardiac index decreased similarly during PEEP (P < 0.01) for all baroreceptor and vagal inputs. This response comprised a decrease in the passive phase of right ventricular filling (P < 0. 01) that was not matched by the estimated increase in active right atrial output. Although the carotid baroreceptor reflex and vagally mediated mechanisms elicit vasoconstriction to compensate for the effects of PEEP on the arterial pressure, these processes fail to defend cardiac output because of the profound effect of PEEP on the passive filling of the right ventricle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery

Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...

متن کامل

Influence of ventilation strategies on survival in severe controlled hemorrhagic shock.

OBJECTIVE To investigate the effect of different ventilation settings on hemodynamic stability in severe controlled hemorrhagic shock. DESIGN Prospective, randomized, controlled animal study. SETTING Research laboratory in a university hospital. SUBJECTS Approximately 35-45 kg domestic pigs. INTERVENTIONS Twenty-four domestic pigs were bled 45 mL/kg (estimated 65% of their calculated bl...

متن کامل

Effects of duty cycle and positive end-expiratory pressure on mucus clearance during mechanical ventilation*.

OBJECTIVES During mechanical ventilation, air flows may play a role in mucus transport via two-phase gas liquid flow. The aim of this study was to evaluate effects of duty cycles and positive end-expiratory pressure on mucus clearance in pigs using mechanical ventilation, and to assess their safety. DESIGN Prospective randomized animal study. SETTING Animal research facility, University of ...

متن کامل

Effect of the Sound of the Holy Quran on Vital Signs and Hemodynamic Changes in Patients Undergoing Orthopedic Surgery

Background and Purpose: The operating room environment is one of the stressful places. Listening to the Holy Quran can produce a comforting effect in this environment. In this study, the effect of listening to the Holy Quran on vital signs and physiological changes was investigated in the patients undergoing orthopedic surgery in Shahid Rajaee Hospital of Qazvin, Iran. Materials and Methods: T...

متن کامل

The ability of pleth variability index to predict the hemodynamic effects of positive end-expiratory pressure in mechanically ventilated patients under general anesthesia.

BACKGROUND Pleth variability index (PVI) is a new algorithm allowing automated and continuous monitoring of respiratory variations in the pulse oximetry plethysmographic waveform amplitude. PVI can predict fluid responsiveness noninvasively in mechanically ventilated patients during general anesthesia. We hypothesized that PVI could predict the hemodynamic effects of 10 cm H2O positive end-expi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 86 1  شماره 

صفحات  -

تاریخ انتشار 1999