Numerical analysis of an osseointegrated prosthesis fixation with reduced bone failure risk and periprosthetic bone loss.

نویسندگان

  • P K Tomaszewski
  • M van Diest
  • S K Bulstra
  • N Verdonschot
  • G J Verkerke
چکیده

Currently available implants for direct attachment of prosthesis to the skeletal system after transfemoral amputation (OPRA system, Integrum AB, Sweden and ISP Endo/Exo prosthesis, ESKA Implants AG, Germany) show many advantages over the conventional socket fixation. However, restraining biomechanical issues such as considerable bone loss around the stem and peri-prosthetic bone fractures are present. To overcome these limiting issues a new concept of the direct intramedullary fixation was developed. We hypothesize that the new design will reduce the peri-prosthetic bone failure risk and adverse bone remodeling by restoring the natural load transfer in the femur. Generic CT-based finite element models of an intact femur and amputated bones implanted with 3 analyzed implants were created and loaded with a normal walking and a forward fall load. The strain adaptive bone remodeling theory was used to predict long-term bone changes around the implants and the periprosthetic bone failure risk was evaluated by the von Mises stress criterion. The results show that the new design provides close to physiological distribution of stresses in the bone and lower bone failure risk for the normal walking as compared to the OPRA and the ISP implants. The bone remodeling simulations did not reveal any overall bone loss around the new design, as opposed to the OPRA and the ISP implants, which induce considerable bone loss in the distal end of the femur. This positive outcome shows that the presented concept has a potential to considerably improve safety of the rehabilitation with the direct fixation implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Analysis and Comparison of Femur Bone in Osseointegrated Amputees and Non Amputees during Daily Activities Bilal

Currently available implants for osseointegration in transfemoral amputees are OPRA system and ISP System which shows many advantages over conventional socket fixation. To overcome the limiting issues like periprosthetic bone losses in osseointegration, a new design was developed. The analysis of both OPRA and New design was compared with a normal femur bone during daily activities. The results...

متن کامل

Novel fixation method of a periprosthetic fracture of the acetabulum using burr holes through the retained cup for locking screw fixation

The incidence of periprosthetic fractures of the acetabulum associated with a total hip arthroplasty is relatively low but may be increasing. Treatment options depend upon the stability of the prosthesis. In this case, we report an unusual fracture pattern where a large portion of posterior column remained osseointegrated to a displaced uncemented acetabular component and removal of the cup wou...

متن کامل

Risk factors for failure after treatment of a periprosthetic fracture of the femur.

Periprosthetic fracture of the femur is an uncommon complication after total hip replacement, but appears to be increasing. We undertook a nationwide observational study to determine the risk factors for failure after treatment of these fractures, examining patient- and implant-related factors, the classification of the fractures and the outcome. Between 1979 and 2000, 1049 periprosthetic fract...

متن کامل

Bioelectric analyses of an osseointegrated intelligent implant design system for amputees.

The projected number of American amputees is expected to rise to 3.6 million by 2050. Many of these individuals depend on artificial limbs to perform routine activities, but prosthetic suspensions using traditional socket technology can prove to be cumbersome and uncomfortable for a person with limb loss. Moreover, for those with high proximal amputations, limited residual limb length may preve...

متن کامل

Periprosthetic Fractures Following Total Knee Arthroplasty

Periprosthetic fractures after total knee arthroplasty may occur in any part of the femur, tibia and patella, and the most common pattern involves the supracondylar area of the distal femur. Supracondylar periprosthetic fractures frequently occur above a well-fixed prosthesis, and risk factors include anterior femoral cortical notching and use of the rotational constrained implant. Periprosthet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 45 11  شماره 

صفحات  -