Simultaneous Determination of Miconazole Nitrate and Metronidazole in Different Pharmaceutical Dosage Forms by Gas Chromatography and Flame Ionization Detector (GC-FID)

نویسندگان

  • Safwan Ashour
  • Nuha Kattan
چکیده

A simple, rapid and precise gas chromatographic method has been developed for the simultaneous determination of miconazole nitrate (MIZ) and metronidazole (MNZ) in tablets and ovules, using a capillary column AE.SE-54 (15 m × 0.53 mm, i.d.) and nitrogen as a carrier gas at a flow rate of 9 mL min(-1). The oven temperature was programmed at 140°C for 3 min, with a rise of 40°C min(-1) up to 180°C (held for 2 min) and then increased to a final temperature of 250°C. The injector and detector port temperatures were maintained at 260°C. Detection was carried out using flame ionization detector. Results of assay and recovery studies were statistically evaluated for its accuracy and precision. The retention times were about 3.50 and 12.90 min for MNZ and MIZ, respectively. Linearity ranges were 50.0-6030.0 and 62.5-2000.0 μg mL(-1) for MNZ and MIZ, with limit of detection values of 2.5 and 3.1 μg mL(-1), respectively. Correlation coefficients (R(2)) of the regression equations were greater than 0.999 in all cases. No interference from any components of pharmaceutical dosage forms or degradation products was observed. According to the validation results, the proposed method was found to be specific, accurate, precise and could be applied to the simultaneous quantitative analysis of MIZ and MNZ in tablets and ovules.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Residual Methylmethacrylate Monomerin Denture Base Resins by Gas Chromatography

Acrylic base resins are widely used in orthopedics and dental surgery. It is generally accepted that due to the incomplete conversion of methyl methacrylate (MMA) monomer to the polymer form during polymerization of the resin, some MMA monomers remain in the hardened material. MMA monomer has been reported to cause abnormalities or lesions in several organs of animals. Study of the literatures ...

متن کامل

Method Development and Validation for the Gc-fid Assay of 17 -estradiol in Pharmaceutical Preparation

A simple and rapid method for determination of 17 -estradiol in pharmaceutical preparation was developed and validated using gas chromatography with flame ionization detection (GC-FID). The solutions of standard and the sample were prepared in methanol. GC separation was performed in about 7.7 min using a 30 m x 0.32 mm I.D. (film thickness 0.25 μm) HP-5 capilary column. Nitrogen was used as c...

متن کامل

Determination of Residual Methylmethacrylate Monomerin Denture Base Resins by Gas Chromatography

Acrylic base resins are widely used in orthopedics and dental surgery. It is generally accepted that due to the incomplete conversion of methyl methacrylate (MMA) monomer to the polymer form during polymerization of the resin, some MMA monomers remain in the hardened material. MMA monomer has been reported to cause abnormalities or lesions in several organs of animals. Study of the literatures ...

متن کامل

Direct analysis of artemisinin from Artemisia annua L. using high-performance liquid chromatography with evaporative light scattering detector, and gas chromatography with flame ionization detector.

Since the isolation of artemisinin 32 years ago, it has been analyzed by different chromatographic techniques. This work compared the analysis of artemisinin from crude plant samples by GC with flame ionization detection (GC-FID) and HPLC with evaporative light scattering detector (HPLC-ELSD). Data is also presented indicating that GC is suitable for the quantification of two of artemisinin pre...

متن کامل

Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2010