Stability of midface fracture repair using absorbable plate and screw system pilot holes drilled and pin placement at angles other than 90°.

نویسندگان

  • Michael A Carron
  • Giancarlo Zuliani
  • Lucio Pereira
  • Maher Abuhamdan
  • Adrianna Thibault
  • Nathan Dau
  • Cynthia Bir
چکیده

IMPORTANCE Conventional plating systems use titanium plates for fixation of fractures, with benefits of strength and biocompatibility. However, titanium plates require that screws be placed at a 90° angle to the pilot holes. In the midface, this becomes extremely difficult. Today, a variety of craniomaxillofacial osteosynthesis systems are available, including resorbable plating systems. Specifically, the KLS Martin Sonic Weld system ultrasonically fuses the plate and the head of the pin when placed and will fill the pilot hole grooves completely even at less than 90° angles, which provides a tremendous advantage in midface fracture repair. OBJECTIVE To determine if the KLS Martin Sonic Weld system provides plate-screw construct stability in human heads even when placed at acute angles at the midface buttresses. DESIGN, SETTING, AND SPECIMENS: Twenty cadaveric head specimens with the mandible removed were prepared by creating osteotomies in the midface buttresses bilaterally. Specimens were defleshed and placed in a 2-part testing rig to hold and position the head for testing in a standard material testing system. Testing was performed at the Wayne State University Bioengineering test laboratories, Detroit, Michigan, using an Instron device and high-speed camera. Specimens were plated on one side of the midface using the KLS Martin Sonic Weld system with pilot holes and pins placed at 90° angles. On the contralateral side, the buttresses were plated with the KLS Martin Sonic Weld system at 60°, 45°, and 30° angles. Data were collected using the TDAS data acquisition system and were compared with matched pairs within each specimen. MAIN OUTCOMES AND MEASURES Ultrasonically vibrated pins placed into absorbable mini-plates at less than 90° angles with the KLS Martin Sonic Weld system were compared with the same amount of stress as the system placed at a 90° angle before demonstrating plate-screw construct failure. RESULTS Fifty-seven paired tests were collected, with 114 total tests. Twenty failures were due to bone breakage, and 94 fixations failed as a result of the plate-screw construct breaking. Fractures fixated with the ultrasonic absorbable plating system placed with screws at all tested angles failed at similar loads to our control plates with pins placed at 90° angles. These results lend the surgeon to successfully reduce fractures in the midface fragments in difficult-to-reach areas and possibly cut down on operative time while improving the chance of achieving a long-lasting adequate reduction. CONCLUSIONS AND RELEVANCE Although there is a measured difference in the laboratory, no clinical difference is observed because the maximum force is not usually encountered. Overall, the clinical scenario indicates absorbable plates to be a viable option in less accessible areas. LEVEL OF EVIDENCE NA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An intramedullary Echidna pin for fixation of comminuted clavicle fractures: a biomechanical study

BACKGROUND Intramedullary fixation of comminuted mid-shaft clavicle fractures has traditionally been employed with satisfactory clinical outcomes; however, pins with smooth surfaces may protrude from the bone and are prone to migration, while some threaded pins are difficult to remove post-operatively. The aim of this proof-of-concept study was to develop and evaluate the biomechanical strength...

متن کامل

Surgical repair of distal femoral fracture in a wild gray wolf (Canis lupus)

A 3-year-old wild gray wolf was referred to the Department of Veterinary Clinical Sciences of ShirazUniversity with a history of car accident. The radiographic examination showed supracondylar distal femoralfracture in right leg. The wolf was pre-medicated by acepromazine followed by induction of anesthesia usinga combination of diazepam and ketamine. Anesthesia was maintained by halothane. The...

متن کامل

Open Reduction of Proximal Interphalangeal Fracture-Dislocation through a Midlateral Incision Using Absorbable Suture Materials

BACKGROUND Fracture-dislocation of the proximal interphalangeal (PIP) joint is a relatively common injury. Various treatments for fracture-dislocation of the PIP joint have been reported. In the present study, we performed open reduction through a midlateral incision using absorbable sutures to reduce the small bone fragments and performed volar plate repair. METHODS We treated nine patients ...

متن کامل

Experimental and Numerical Study of Perforated Steel Plate Shear Panels

Thin perforated Steel Plate Shear (SPS) Walls are among the most common types of energy dissipating systems. The applied holes reduce the shear strength of the plate and allow to decrease the profile size of the members at the boundary of the panel when these systems are used in the typical design of structures. On the other hand, the different fracture locations of these panels are visible whe...

متن کامل

شکست وسایل تثبیت ستون فقرات

This was a retrospective review of a consecutive series of patients with spinal disease in year 2000, who underwent posterior fusion and instrumentation with Harrington distraction and Cotrel-Dobousset system to evaluate causes of hardware failure. Many cases of clinical failure has been observed in spinal instrumentation used in spinal disorder like spondylolisthesis, fractures, deformities, …...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JAMA facial plastic surgery

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2014