An in vitro biomechanical comparison of an interlocking nail system and dynamic compression plate fixation of ostectomized equine third metacarpal bones.
نویسندگان
چکیده
OBJECTIVE To compare the mechanical properties of two stabilization methods for ostectomized equine third metacarpi (MC3): (1) an interlocking nail system and (2) two dynamic compression plates. Animal or Sample Population-Ten pairs of adult equine forelimbs intact from the midradius distally. METHODS Ten pairs of equine MC3 were divided into two test groups (five pairs each): caudocranial four-point bending and torsion. Interlocking nails (6 hole, 13-mm diameter, 230-mm length) were placed in one randomly selected bone from each pair. Two dynamic compression plates one dorsally (12 hole, 4.5-mm broad) and one laterally (10 hole, 4.5-mm broad) were attached to the contralateral bone from each pair. All bones had 1 cm mid-diaphyseal ostectomies. Five construct pairs were tested in caudocranial four-point bending to determine stiffness and failure properties. The remaining five construct pairs were tested in torsion to determine torsional stiffness and yield load. Mean values for each fixation method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS Mean (+/-SEM) values for the MC3-interlocking nail composite and the MC3-double plate composite, respectively, in four-point bending were: composite rigidity, 3,454+/-407.6 Nm/rad and 3,831+/-436.5 Nm/rad; yield bending moment, 276.4+/-40.17 Nm and 433.75+/-83.99 Nm; failure bending moment, 526.3+/-105.9 Nm and 636.2+/-27.77 Nm. There was no significant difference in the biomechanical values for bending between the two fixation methods. In torsion, mean (+/-SEM) values for the MC3-interlocking nail composite and the MC3-double plate composite were: composite rigidity, 124.1+/-16.61 Nm/rad and 262.4+/-30.51 Nm/rad; gap stiffness, 222.3+/-47.32 Nm/rad and 1,557+/-320.9 Nm/rad; yield load, 94.77+/-7.822 Nm and 130.66+/-20.27 Nm, respectively. Composite rigidity, gap stiffness, and yield load for double plate fixation were significantly higher compared with interlocking nail fixation in torsion. CONCLUSIONS No significant differences in biomechanical properties were identified between an interlocking nail and double plating techniques for stabilization of ostectomized equine MC3 in caudocranial four-point bending. Double plating fixation was superior to interlocking nail fixation in torsion.
منابع مشابه
Interlocking Nailing Versus Interlocking Plating in Intra-articular Calcaneal Fractures: A Biomechanical Study.
BACKGROUND Open reduction and internal fixation with a plate is deemed to represent the gold standard of surgical treatment for displaced intra-articular calcaneal fractures. Standard plate fixation is usually placed through an extended lateral approach with high risk for wound complications. Minimally invasive techniques might avoid wound complications but provide limited construct stability. ...
متن کاملDevelopment of an in vitro three dimensional loading-measurement system for long bone fixation under multiple loading conditions: a technical description
The purpose of this investigation was to design and verify the capabilities of an in vitro loading-measurement system that mimics in vivo unconstrained three dimensional (3D) relative motion between long bone ends, applies uniform load components over the entire length of a test specimen, and measures 3D relative motion between test segment ends to directly determine test segment construct stif...
متن کاملResults of Plate Fixation of Third Metacarpal and Metatarsal Diaphyseal Fractures
Diaphyseal fractures of the third metacarpal (MCIII) or metatarsal (MTIII) bones are not common in horses, although they are seen regularly in equine athletes. These fractures are as many as one third of all long-bone fractures in the horse. Treatment options for MCIII/MTIII fractures include internal fixation, external coaptation, and a combination of the two. The most stable treatment method ...
متن کاملBiomechanical comparison of a novel castless arthrodesis plate with T-plate and cross pin techniques for canine partial carpal arthrodesis.
OBJECTIVES To describe a novel canine castless partial carpal arthrodesis plate (par-CA) and its ex vivo biomechanical comparison with T-plate and cross pinning techniques for canine partial carpal arthrodesis. METHODS The three implant systems were applied to three cohorts of six forelimbs from Greyhounds euthanatized for reasons unrelated to the study. Intercarpal and carpometacarpal palmar...
متن کاملInternal fixation of shaft humerus fractures by dynamic compression plate or interlocking intramedullary nail: a prospective, randomised study
Compare the results of internal fixation of shaft of humerus fractures using dynamic compression plating (DCP) or antegrade interlocking intramedullary nail (IMN). Fifty patients with diaphyseal fracture of the shaft of the humerus and fulfilling the inclusion criterion were randomly assigned to one of the two groups. Twenty-five patients were managed with closed antegrade interlocking intramed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Veterinary surgery : VS
دوره 28 5 شماره
صفحات -
تاریخ انتشار 1999