Prevalence of High-Riding Vertebral Artery and Morphometry of C2 Pedicles Using a Novel Computed Tomography Reconstruction Technique
نویسندگان
چکیده
STUDY DESIGN Cross-sectional, matched-pair comparative study. PURPOSE To determine whether a thin-sliced pedicular-oriented computed tomography (TPCT) scan reconstructed from an existing conventional computed tomography (CCT) scan is more accurate for identifying vertebral artery groove (VAG) anomalies than CCT. OVERVIEW OF LITERATURE Posterior atlantoaxial transarticular screw fixation and C2 pedicle screws can cause vertebral artery (VA) injury. Two anatomic variations of VAG anomalies are associated with VA injury: a high-riding VA (HRVA) and a narrow pedicle of the C2 vertebra. CCT scan is a reliable method used to evaluate VAG anomalies; however, its accuracy level remains debatable. Literature comparing the prevalence of C2 VAG anomalies between CCT and TPCT is limited. METHODS A total of 200 computed tomography scans of the upper cervical spine obtained between January 2008 and December 2011 were evaluated for C2 VAG anomalies (HRVA and narrow pedicular width) using CCT and TPCT. The prevalence of C2 VAG anomalies was compared using these two different measurement methods via a McNemar's test. RESULTS Of the 200 patients studied, 23 HRVA (6.01%; 95% confidence interval [CI], 3.61%-8.39%) were detected with CCT, whereas 66 HRVA (16.54%; 95% CI, 12.85%-20.23%) were detected with TPCT (p<0.001). Sixty-two narrow pedicles (15.58%; 95% CI, 11.99%-19.15%) were detected with CCT, whereas 90 narrow pedicles (22.83%; 95% CI, 18.58%-26.87%) were detected with TPCT (p<0.001). CONCLUSIONS VAG anomalies are commonly observed. A preoperative evaluation using TPCT reconstructed from an existing CCT revealed a significantly higher prevalence of C2 VAG anomalies than did CCT and showed comparable prevalence to previously published studies using more sophisticated and higher risk techniques. Therefore, we propose TPCT as an alternative preoperative evaluation for C2 screw placement and trajectory planning.
منابع مشابه
Atlantoaxial transarticular screw fixation for a high-riding vertebral artery.
STUDY DESIGN The feasibility of inserting a screw for the narrow isthmus with a high-riding vertebral artery was evaluated in patients subjected to posterior atlantoaxial transarticular screw fixation. OBJECTIVE To demonstrate the feasibility of inserting bilateral screws and obtaining a stable atlantoaxial complex for patients with a high-riding vertebral artery. SUMMARY OF BACKGROUND DATA...
متن کاملCT analysis of anatomical variation and injury affecting posterior pedicle screw fixation for unstable Hangman fractures
The aim of this study was to evaluate the anatomical variations and injuries in patients with unstable Hangman fractures that affected the posterior pedicle screw placement of C2 to C3 and retrospectively review our experience with management of these fractures. Clinical data were reviewed in 72 patients with unstable Hangman fractures, especially using 3-dimensional computed tomography (3D-CT)...
متن کاملThree-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography
The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...
متن کاملPosterior atlantoaxial fusion using a C2 transverse foramen-penetrating screw: A technical note
Background Although recent development of screw instrumentation techniques for rigid fixation of the atlantoaxial joint has increased surgical options, patients in whom screws of any type cannot be safely placed are sometimes encountered. We present a unique surgical technique for C1-2 transarticular screw placement utilizing a novel trajectory. Methods A 35-year-old male with a history of Do...
متن کاملC1 posterior arch screw as an auxiliary anchor in posterior reconstruction for atlantoaxial dislocation associated with type II odontoid fracture: a case report and review of the literature
INTRODUCTION Although pedicle or lateral mass screws are usually chosen to fix atlantoaxial (C1-C2) instability, there is an increased risk for vertebral artery (VA) injury when used in patients with bone or arterial anomalies or osteoporotic bone. Here we report the C1 posterior arch screw as a new technique for upper cervical fixation. CASE DESCRIPTION A 90-year-old man complained of upper ...
متن کامل