Comparison With Conventional Indicator Dilution Curve Parameters in Phantom and Canine Models

نویسندگان

  • Neal L. Eigler
  • Andreas Zeiher
  • James S. Whiting
  • James S. Forrester
چکیده

The system mean transit time (T,^) of the impulse response function describing contrast material transit through the coronary circulation was determined from serial digital angiographic images. The linearity, reproducibility, and relations with regional myocardial perfusion and conventional time-density curve parameters, time to peak concentration (TPC), and exponential washout rate (k) were assessed in a dynamic flow x-ray phantom (n=46) and in six open-chest dogs (n=102) while coronary flow was altered by stenosis and/or hyperemic stimuli. In the phantom studies, the inverse of the system mean transit time (T^,"') closely predicted flow/volume (r=0.99, slope=0.99). In dogs, T,̂ " was independent of the shape of the contrast bolus injection (single or double-peaked), class of contrast agent (ionic or nonionic), the type of hyperemic stimulus (dipyridamole, dipyridamole plus norepinephrine, transient total occlusion, or ionic contrast media), and was highly reproducible between adjacent myocardial regions served by the same artery (r=0.98±0.01). There was a strong correlation between T^," and regional coronary flow for stenotic and/or hyperemic vessels (r=0.94, distribution volume=14.9 ml/100 g) over a wide range (0-514 ml/min/100 g). T,̂ " performed better than conventional time-density curve parameters TPC"' and k for predicting phantom flow/volume ratios and regional myocardial blood flow in the dog. These data suggest that both digital coronary angiography and coronary contrast transit can be modeled as linear systems and that impulse response analysis may provide accurate and reproducible estimates of regional myocardial blood flow. (Circulation Research 1989;64:853-866)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Diagnostic Value of Cast Analyzer X Iranian Software versus Curve Expert Software for Arch Form Construction based on Mathematical Models

  Objective: For the assessment of primary arch form, different methods have been used including qualitative classifications, inter-canine and inter-molar widths and quantitative and numerical methods using mathematical models. The purpose of this study was to compare the validity and reliability of Cast Analyzer X Iranian software with those of Curve Expert Professional version 1.1 for arch fo...

متن کامل

System modeling and identification in indicator dilution method for assessment of Ejection Fraction and Pulmonary Blood Volume

Clinically relevant cardiovascular parameters, such as pulmonary blood volume (PBV) and ejection fraction (EF), can be assessed through indicator dilution techniques. Among these techniques, which are typically invasive due to the need for central catheterization, contrast ultrasonography provides a new emerging minimally invasive option. PBV and EF are then measured by a dilution system identi...

متن کامل

Estimation of Runoff using Modified SCS Models

In recent decades, due to the importance of watershed management programs and the need for adequate information and correct estimation of rainfall and runoff, many conceptual models have been proposed. These models have parameters that must be estimated according to observational data. However, finding the optimal values for the parameters of simulation models has always faced uncertainty. One ...

متن کامل

Arterial Blood Flow Patterns in Human Subjects and Their Effect on Indicator Dilution Curves

Indicator dilution curves obtained from various systemic arterial sampling sites are commonly used for analysis of blood flow, cardiac shunts and valvular regurgitation, and for study of segments of the blood volume. It is generally assumed that the contour of such curves is largely determined by the passage and dilution of the indicator in the central circulation and that changes occurring dur...

متن کامل

Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output.

A new indicator dilution technique for measurement of cardiac output is described. Lithium chloride is injected via a central venous catheter and its dilution curve measured in arterial blood using a lithium-selective electrode. We assessed the lithium dilution cardiac output measurement (LiDCO) and a conventional thermodilution cardiac output measurement (ThDCO) by comparing the results of bot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005