Cardiomyopathy induced by artificial cardiac pacing: myth or reality sustained by evidence?

نویسندگان

  • Andrés Di Leoni Ferrari
  • Anibal Pires Borges
  • Luciano Cabral Albuquerque
  • Carolina Pelzer Sussenbach
  • Priscila Raupp da Rosa
  • Ricardo Medeiros Piantá
  • Mario Wiehe
  • Marco Antônio Goldani
چکیده

Implantable cardiac pacing systems are a safe and effective treatment for symptomatic irreversible bradycardia. Under the proper indications, cardiac pacing might bring significant clinical benefit. Evidences from literature state that the action of the artificial pacing system, mainly when the ventricular lead is located at the apex of the right ventricle, produces negative effects to cardiac structure (remodeling, dilatation) and function (dissinchrony). Patients with previously compromised left ventricular function would benefit the least with conventional right ventricle apical pacing, and are exposed to the risk of developing higher incidence of morbidity and mortality for heart failure. However, after almost 6 decades of cardiac pacing, just a reduced portion of patients in general would develop these alterations. In this context, there are not completely clear some issues related to cardiac pacing and the development of this cardiomyopathy. Causality relationships among QRS widening with a left bundle branch block morphology, contractility alterations within the left ventricle, and certain substrates or clinical (previous systolic dysfunction, structural heart disease, time from implant) or electrical conditions (QRS duration, percentage of ventricular stimulation) are still subjects of debate. This review analyses contemporary data regarding this new entity, and discusses alternatives of how to use cardiac pacing in this context, emphasizing cardiac resynchronization therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rate smoothing induced ventricular arrhythmia and syncope: a new device-induced proarrhythmia.

A 74-year-old male presented to our emergency room with history of sudden onset palpitations associated with syncope. He had a single-chamber implantable cardioverter defibrillator implanted for secondary prevention of sudden cardiac death due to ischaemic cardiomyopathy. Interrogation of the device revealed episodes of non-sustained ventricular tachycardia (NSVT) at 220 ms. Post-tachycardia, a...

متن کامل

A memorable experience.

The electrocardiographic phenomenon of cardiac memory results from aberrant ventricular activation and causes transient ECG features that can mimic ischaemia. We present the case of a patient with ischaemic cardiomyopathy who exhibited evidence of T-wave memory in the setting of multiple episodes of non-sustained ventricular tachycardia that were triggered by an insect bite.

متن کامل

Premature Ventricular Contractions and Non-sustained Ventricular Tachycardia: Association with Sudden Cardiac Death, Risk Stratification, and Management Strategies

Premature ventricular contractions (PVCs) and non-sustained ventricular tachycardia (NSVT) are frequently encountered and a marker of electrocardiomyopathy. In some instances, they increase the risk for sustained ventricular tachycardia, ventricular fibrillation, and sudden cardiac death. While often associated with a primary cardiomyopathy, they have also been known to cause tachycardia-induce...

متن کامل

Management of nonsustained ventricular tachycardia guided by electrophysiological testing.

Two hundred eighty patients with spontaneous nonsustained ventricular tachycardia were treated based on the results of electrophysiological testing. Seventy-nine patients had no evidence of structural heart disease, 134 had coronary artery disease, 43 had idiopathic dilated cardiomyopathy, and 24 patients had miscellaneous types of heart disease. Sustained monomorphic ventricular tachycardia wa...

متن کامل

A case of premature ventricular contractions, ventricular tachycardia, and arrhythmic storm induced by right ventricular pacing during cardiac resynchronization therapy: Electrophysiological mechanism and catheter ablation.

A 77-year-old man with ischemic cardiomyopathy and a cardiac resynchronization therapy-defibrillator (CRT-D) device came to our attention due to incessant ventricular tachycardia and multiple implantable cardioverter defibrillator (ICD) shocks. An electrocardiogram showed non-sustained monomorphic ventricular tachycardias (NSVTs) constantly occurring after each biventricular stimulation. During...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2014