A new bioimpedance research device (BIRD) for measuring the electrical impedance of acupuncture meridians.

نویسندگان

  • Felix Wu Shun Wong
  • Chi Eung Danforn Lim
  • Warren Smith
چکیده

OBJECTIVES The aim of this article is to introduce an electrical bioimpedance device that uses an old and little-known impedance measuring technique to study the impedance of the meridian and nonmeridian tissue segments. DESIGN Three (3) pilot experimental studies involving both a tissue phantom (a cucumber) and 3 human subjects were performed using this BIRD-I (Bioimpedance Research Device) device. This device consists of a Fluke RCL meter, a multiplexer box, a laptop computer, and a medical-grade isolation transformer. Segment and surface sheath (or local) impedances were estimated using formulae first published in the 1930s, in an approach that differs from that of the standard four-electrode technique used in most meridian studies to date. RESULTS Our study found that, when using a quasilinear four-electrode arrangement, the reference electrodes should be positioned at least 10 cm from the test electrodes to ensure that the segment (or core) impedance estimation is not affected by the proximity of the reference electrodes. A tissue phantom was used to determine the repeatability of segment (core) impedance measurement by the device. An applied frequency of 100 kHz was found to produce the best repeatability among the various frequencies tested. In another preliminary study, with a segment of the triple energizer meridian on the lower arm selected as reference segment, core resistance-based profiles around the lower arm showed three of the other five meridians to exist as local resistance minima relative to neighboring nonmeridian segments. The profiles of the 2 subjects tested were very similar, suggesting that the results are unlikely to be spurious. CONCLUSIONS In electrical bioimpedance studies, it is recommended that the measuring technique and device be clearly defined and standardized to provide optimal working conditions. In our study using the BIRD I device, we defined our standard experimental conditions as a test frequency of 100 kHz and the position of the reference electrodes of at least 10 cm from the test electrodes. Our device has demonstrated potential for use in quantifying the degree of electrical interconnection between any two surface-defined test meridian or nonmeridian segments. Issues arising from use of this device and the measurement Horton and van Ravenswaay technique were also presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and evaluation of a novel four-electrode device system for monitoring skin impedance.

Qi, meridians, and acupoints are important issues in Chinese medicine. One of the theories claims that acupuncture points and meridians have unique electrical properties. The associations between acupuncture points or meridians and special electrical properties are still under debate. In the current study, we introduced and explained a device for this kind of research and evaluated the reliabil...

متن کامل

Electrical Impedance of Acupuncture Meridians: The Relevance of Subcutaneous Collagenous Bands

BACKGROUND The scientific basis for acupuncture meridians is unknown. Past studies have suggested that acupuncture meridians are physiologically characterized by low electrical impedance and anatomically associated with connective tissue planes. We are interested in seeing whether acupuncture meridians are associated with lower electrical impedance and whether ultrasound-derived measures--speci...

متن کامل

Electrical properties of acupuncture points and meridians: a systematic review.

According to conventional wisdom within the acupuncture community, acupuncture points and meridians are special conduits for electrical signals. This view gained popularity after anecdotal reports and clinical studies asserted that these anatomical structures are characterized by lower electrical impedance compared to adjacent controls. To ascertain whether evidence exists to support or refute ...

متن کامل

Electrical impedance along connective tissue planes associated with acupuncture meridians

BACKGROUND Acupuncture points and meridians are commonly believed to possess unique electrical properties. The experimental support for this claim is limited given the technical and methodological shortcomings of prior studies. Recent studies indicate a correspondence between acupuncture meridians and connective tissue planes. We hypothesized that segments of acupuncture meridians that are asso...

متن کامل

Characterisation of human skin impedance at acupuncture point PC4 Ximen and pericardium meridian using the four-electrode method.

INTRODUCTION Traditional Chinese medicine offers several theories to explain the mechanism of acupuncture. One of these theories proposes that acupuncture points and meridians have unique electrical properties and their electrical skin impedance is lower than surrounding areas. The aim of this study was to evaluate the differences in electrical skin impedance between PC4 and the pericardium mer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of alternative and complementary medicine

دوره 16 3  شماره 

صفحات  -

تاریخ انتشار 2010