Needle-based refractive index measurement using low-coherence interferometry.

نویسندگان

  • Adam M Zysk
  • Steven G Adie
  • Julian J Armstrong
  • Matthew S Leigh
  • Alexandre Paduch
  • David D Sampson
  • Freddy T Nguyen
  • Stephen A Boppart
چکیده

We present a novel needle-based device for the measurement of refractive index and scattering using low-coherence interferometry. Coupled to the sample arm of an optical coherence tomography system, the device detects the scattering response of, and optical path length through, a sample residing in a fixed-width channel. We report use of the device to make near-infrared measurements of tissues and materials with known optical properties. The device could be used to exploit the refractive index variations of tissue for medical and biological diagnostics accessible by needle insertion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry

In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...

متن کامل

Air etalon facilitated simultaneous measurement of group refractive index and thickness using spectral interferometry.

A simple method based on air etalons of a transparent cavity is proposed to simultaneously measure the group refractive index and thickness of a transparent optical plate by spectral domain low coherence interferometry. In this method, only a single beam path is needed in contrast to the two beam paths, the reference and sample arms, of the conventional Michelson interferometer. An empty cavity...

متن کامل

Separating the scattering and absorption coefficients using the real and imaginary parts of the refractive index with low-coherence interferometry.

We present an analytical method that yields the real and imaginary parts of the refractive index (RI) from low-coherence interferometry measurements, leading to the separation of the scattering and absorption coefficients of turbid samples. The imaginary RI is measured using time-frequency analysis, with the real part obtained by analyzing the nonlinear phase induced by a sample. A derivation r...

متن کامل

One-dimensional inverse scattering problem for optical coherence tomography

Optical coherence tomography is a non-invasive imaging technique based on the use of light sources exhibiting a low degree of coherence. Low-coherence interferometric microscopes have been successful in producing internal images of thin pieces of biological tissue; typically samples of the order of 1 mm in depth have been imaged, with a resolution of the order of 10 μm in some portions of the s...

متن کامل

Simultaneous measurement of refractive index and thickness by combining low-coherence interferometry and confocal optics.

We propose and demonstrate novel methods that enable simultaneous measurements of the phase index, the group index, and the geometrical thickness of an optically transparent object by combining optical low-coherence interferometer and confocal optics. The low-coherence interferometer gives information relating the group index with the thickness, while the confocal optics allows access to the ph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 32 4  شماره 

صفحات  -

تاریخ انتشار 2007