Short-term follow-up of palpable breast lesions with benign imaging features: evaluation of 375 lesions in 320 women.
نویسندگان
چکیده
OBJECTIVE The purpose of this study was to evaluate the feasibility of short-term follow-up of palpable masses that have benign imaging features. MATERIALS AND METHODS The cases of all women with round, oval, or lobular palpable masses with circumscribed margins and homogeneous ultrasound echotexture for which short-term follow-up was recommended from July 1997 through December 2003 were retrospectively identified. Evaluation was by ultrasound and/or mammography and focused clinical examination. Outcome was assessed with imaging or clinical follow-up lasting at least 12 months. The cancer incidence for palpable lesions was compared with that for nonpalpable lesions recommended for short-term follow-up. RESULTS In 379 women, 443 palpable masses with benign features for which short-term follow-up was recommended were identified. Outcome data were available on 375 masses in 320 women. Lesions were evaluated with mammography and ultrasound (n = 186) or ultrasound alone (n = 189). Masses were typically identified only with ultrasound (n = 258, 68.8%); were oval (n = 275, 73.3%), of equal density to normal breast tissue on mammograms (n = 95 on 117 mammograms, 81.2%), and hypoechoic (n = 336 in 372 ultrasound examinations, 90.3%); and were prospectively believed to be fibroadenoma (n = 304, 81.1%). Eighty-five lesions (22.7%) were biopsied soon after evaluation, and one 1.5-mm ductal carcinoma in situ was diagnosed. At follow-up (mean, 2.7 years), 26 lesions (6.9%) had grown. Twenty-four of the 26 lesions were biopsied, and no cancer was diagnosed. The overall cancer prevalence was similar for palpable (0.3%) and nonpalpable (1.6%) masses. The cost of short-term follow-up was less than that of biopsy. CONCLUSION Short-term follow-up is a reasonable alternative to biopsy of palpable breast lesions with benign imaging features, particularly for young women with probable fibroadenoma.
منابع مشابه
Differentiation of benign and malignant breast lesions by apparent diffusion coefficient value in mass and non-mass lesions
Background: Diffusion-weighted imaging (DWI) is one of methods in evaluation of breast lesions. We aimed to investigate the apparent diffusion coefficient (ADC) values in breast tumors and their accuracy in differentiating benign versus malignant lesions. Methods: In this cross-sectional study, 72 patients with 88 breast lesions were investigated by 1.5-T breast MRI from 2015 to 2017 in Athari...
متن کاملMODIFIED TRIPLE TEST SCORE (MTTS) FOR EVALUATION OF PALPABLE BREAST MASSES IN WOMEN UNDER AGE 40
ABSTRACT Background: Evaluation of breast masses in women under 40 years old starts with a Triple Test Score (TTS) which is composed of clinical breast examination, mammography and fine needle aspiration. Increased breast density in this age group decreases the sensitivity of mammography. So deciding whether to biopsy such nondiagnostic lesions or not is subject to challenge. Breast masses up ...
متن کاملShort-interval follow-up mammography: are we doing the right thing?
The American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) (1) was designed to standardize the interpretation and reporting of mammography results by providing six well-defined assessment categories and standard recommendations for follow-up. One of the six assessment categories is “probably benign – short-interval follow-up recommended” or BI-RADS 3. The creation of t...
متن کاملUltrasonographic features and clinical implications of benign palpable breast lesions in young women
PURPOSE The purpose of this study was to describe the breast ultrasonography (US) features and to investigate whether performing a core biopsy is warranted in young women having palpable solid breast masses. METHODS A total of 76 solid palpable masses in 68 consecutive women (≤25 years old) underwent tissue diagnosis by percutaneous core biopsy. Two radiologists, who were blinded to the clini...
متن کاملEffectiveness of assigning BI-RADS category-3 to breast lesion with respect to follow-up.
OBJECTIVE To determine the effectiveness of assigning BI-RADS category-3 to breast lesion with respect to follow-up. STUDY DESIGN A cohort study. PLACE AND DURATION OF STUDY Radiology Department, the Aga Khan University Hospital, Karachi, from January 2002 to December 2004. PATIENTS AND METHODS Women undergoing X-ray mammography and assigned BI-RADS category-3 and recommended short-term (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJR. American journal of roentgenology
دوره 193 6 شماره
صفحات -
تاریخ انتشار 2009