Medium-term results with the Press Fit Condylar (PFC) Sigma knee prosthesis the Wrightington experience.

نویسندگان

  • Saeed H Zaki
  • Imran Rafiq
  • Amit Kapoor
  • Videsh Raut
  • Anil K Gambhir
  • Martyn L Porter
چکیده

The PFC Sigma total knee was introduced in 1997, incorporating a number of design changes. We report the mid-term results of a consecutive series of PFC Sigma knee arthroplasties performed between November 1997 and December 1998. Out of a total of 156 patients (166 knees), 5 patients (5 knees) were lost to follow-up and 6 patients (6 knees) died of unrelated causes. This left 145 patients (155 knees), 90 female and 55 male, with a mean age of 70 years (range, 53-88) and an average follow-up of 90 months (range, 84-96). Posterior cruciate retaining components were used in 136 knees (88%) and posterior-stabilized in 19 (12%). The patella was resurfaced in 74 (48%) knees. Follow-up was at 3, 6 and 12 months, then yearly. Preoperative American Knee Society and Oxford scores were compared with follow-up scores. The Knee Society radiological score was used for radiographic assessment. One knee (0.6%) was revised due to aseptic loosening. One knee (0.6%) had superficial wound infection, which settled with oral antibiotics. Two knees became deeply infected. Of these, one resolved following early debridement, the other developed chronic infection. Using revision for any reason as the end-point our cumulative success rate was 99.4%. The mean preoperative Knee score improved from 45 (30-65) to 84 (45-92), Functional score from 38 (25-55) to 73 (50-95) and Oxford score from 43 (33-52) to 17 (14-29). Radiographic review showed radiolucent lines in 54 (35%) tibial and 17 (11%) femoral components. The Radiological Knee Society score was less than 4 in all except one tibia where the score was 7. Our study shows excellent clinical results with the PFC Sigma total knee replacement after almost eight years follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system.

PURPOSE To evaluate the midterm results of 50 patients who underwent total knee replacement using Press Fit Condylar (PFC) Sigma system. METHODS We retrospectively reviewed 87 consecutive cases (50 patients with 37 bilateral cases) of PFC Sigma total knee replacement performed between January 1998 and December 1999. Patients were evaluated clinically and radiographically by an independent obs...

متن کامل

Patellar clunk syndrome in fixed-bearing posterior-stabilised versus cruciate-substituting prostheses.

PURPOSE To compare the outcome of fixed-bearing posterior-stabilised versus cruciate-substituting prostheses in 46 patients who underwent primary bilateral total knee replacement (TKR). METHODS Records of 35 women and 11 men aged 54 to 78 (mean, 67) years who underwent primary bilateral TKR for osteoarthritis (n=44) and rheumatoid arthritis (n=2) were retrospectively reviewed. A fixed-bearing...

متن کامل

Comparison of the Clinical Outcomes after Total Knee Arthroplasty with the LCS Rotating Platform Mobile Bearing Knee System and the PFC Sigma RP-F Mobile Bearing Knee System

BACKGROUND We compared clinical outcomes after total knee arthroplasty with the Low Contact Stress (LCS) rotating platform mobile bearing knee system and the Press Fit Condylar Sigma rotating platform high flexion (PFC Sigma RP-F) mobile bearing knee system. METHODS Fifty cases of total knee arthroplasty were performed with the PFC Sigma RP-F mobile bearing knee system and sixty-one cases wer...

متن کامل

Fracture of the Anterior Locking Flange of a Total Knee Arthroplasty Polyethylene Liner Presenting with Pain following Knee Replacement

INTRODUCTION Fracture of the modern polyethylene insert of a total knee arthroplasty is rare. We describe the first case of a fractured anterior locking flange of the commonly used Depuy Press-fit Condylar (PFC) Sigma prosthesis. CASE REPORT The 80 year old Caucasian gentleman presented 8 years following previously uncomplicated and successful primary total knee replacement with pain, swellin...

متن کامل

Revision TKA with a condylar constrained prosthesis using metaphyseal and surface cementation: a minimum 6-year follow-up analysis

BACKGROUND The increasing number of revision knee arthroplasty result in the more frequently use of a constraint implant but results from previous reports are difficult to interpret. The purpose of this study was to compare the long-term outcomes of superficial cemented versus metaphyseal cemented in revision total knee arthroplasty with a condylar constrained arthroplasty. METHODS The study ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 73 1  شماره 

صفحات  -

تاریخ انتشار 2007