Long-term stabilized blood samples as controls for flow cytometric HLA-B27 screening: a feasibility study.
نویسندگان
چکیده
BACKGROUND Long-term stabilized blood samples are potentially useful as positive or negative procedure controls for flow cytometric HLA-B27 screening, and could serve as test samples in an external quality assessment (EQA) scheme. We evaluated long-term stabilized whole blood specimens as prepared for the UK NEQAS for Leucocyte Immunophenotyping EQA scheme (Sheffield, UK). METHODS Peripheral blood samples were obtained from nine blood bank donors with known HLA-B typing. Short-term stabilization with Trans-FIXtrade mark was performed before shipment to Sheffield. Thereafter, long-term stabilization was performed. Commercially available HLA-B27 mAb were tested periodically between 1 week and 12 months on (i) fresh, (ii) short-term stabilized, and (iii) long-term stabilized blood samples using a stain, lyse, and wash technique. We compared the forward scatter (FSC), sideward scatter (SSC), and fluorescence signals of lymphocytes as a function of time. Furthermore, a pilot send-out with stabilized blood samples of four blood bank donors was distributed among the participants to the Benelux EQA scheme for HLA-B27 screening, and results were compared with historical EQA data obtained using nonstabilized blood samples from the same donors. RESULTS There were no major effects on FSC and SSC characteristics of lymphocytes. Background fluorescence of stabilized samples increased and specific fluorescence of stabilized HLA-B27 positive samples decreased as compared with fresh samples. However, discrimination between the investigated HLA-B27 positive and HLA-B27 negative samples remained feasible poststabilization. In the pilot send-out, the results obtained with stabilized samples were less concordant than with the corresponding fresh samples due to variable quality of the stabilized samples. CONCLUSION Long-term stabilized whole blood samples are potentially useful as true HLA-B27 positive and true HLA-B27 negative control cells for daily and longitudinal quality control of flow cytometric HLA-B27 screening. In the same way, long-term stabilized samples may be used for EQA purposes. However, these samples are currently not feasible for reagent validation purposes. Extensive quality control of long-term stabilized samples is necessary before distribution in multicenter surveys.
منابع مشابه
HLA-B27 screening by flow cytometry.
A flow cytometric assay for lymphocyte HLA-B27 expression using a two-color direct immunofluorescent assay was compared to traditional microlymphocytotoxicity testing on 209 clinical samples. For the flow cytometric assay, whole blood was mixed with a monoclonal anti-B27 conjugated to fluorescein-isothiocyanate (FITC) and anti-CD3 conjugated to phycoerythrin (PE). The samples were analyzed with...
متن کاملFlow Cytometric Human Leukocyte Antigen-B27 Typing with Stored Samples for Batch Testing
BACKGROUND Flow cytometry (FC) HLA-B27 typing is still used extensively for the diagnosis of spondyloarthropathies. If patient blood samples are stored for a prolonged duration, this testing can be performed in a batch manner, and in-house cellular controls could easily be procured. In this study, we investigated various methods of storing patient blood samples. METHODS WE COMPARED FOUR STORA...
متن کاملDistribution of HLA-B*27 Alleles in Pa-tients with Ankylosing Spondylitis in Iran
Background: HLA-B*27 is strongly associated with ankylosing spondylitis (AS). It represents a family of alleles that differ among ethnic groups. Objective: The aim of this study was to determine the distribution of HLA-B*27 alleles in AS patients and healthy controls in Isfahan (Iran). Methods: Sixty AS patients and 430 healthy blood donors were selected. All subjects were HLA-B*27 positive by ...
متن کاملFlow Cytometric Measurement of CD41/CD61 and CD42b Platelet Receptors and Clotting Assay of Platelet Factor 3 During Long Term-Storage of Platelet Concentrates
Background: The purpose of the present in vitro study was to evaluate the effect of long term storage of conventional platelet concentrates (PCs) on major platelet receptors CD42b and CD41/CD61 by flow cytometry method and also measuring the overall platelet procoagulant activity status using platelet factor 3 (PF3) assay. Materials and Methods: Six random units of conventional platelet conce...
متن کاملHLA-B27 phenotyping with flow cytometry: further improvement by multiple monoclonal antibodies.
To establish the optimal flow cytometric method for HLA-B27 phenotyping, we compared several strategies, using three monoclonal anti-B27 antibodies (from the HLA-ABC-m3, GS145.2, and FD705 clones). We used a triple-color direct immunofluorescence assay, including a T-lymphocyte-specific antibody as an internal control and an anti-HLA-Bw4 antibody. Blood samples from >400 subjects were tested. F...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cytometry. Part B, Clinical cytometry
دوره 74 3 شماره
صفحات -
تاریخ انتشار 2008