Strontium (II)-Selective Potentiometric Sensor Based on Ester Derivative of 4-tert-butylcalix(8)arene in PVC Matrix
نویسندگان
چکیده
Membranes of 4-tert-butylcalix(8)arene-octaacetic acid octaethyl ester (I) as an electroactive material, sodium tetraphenyl borate (NaTPB) as an anion excluder, and tri-n-butyl phosphate (TBP) as a solvent mediator in poly(vinyl chloride) (PVC) matrix have been tried for a strontium-selective sensor. The best performance was exhibited by the membrane having a composition 5:100:150:2 (I: PVC: TBP: NaTPB (w/w)). This sensor exhibits a good potentiometric response to Sr over a wide concentration range (3.2 × 10 –5 –1.0 × 10 –1 M) with a Nernstian slope (30 mV/ decade). The response time of the sensor is 10 s and it has been used for a period of four months without any drift in potentials. The selectivity coefficient values are in the order of 0.01 for mono-, bi-, and trivalent cations which indicate a good selectivity for Sr over a large number of cations. The useful pH range for the sensor was found to be 3-10 and it works well in mixtures with non-aqueous content up to 25 % (v/v). The sensor has been used as an indicator electrode in the potentiometric titration of Sr against EDTA.
منابع مشابه
A coated wire-type lead(II) ion-selective electrode based on a phosphorylated calix[4]arene derivative.
The preparation of a lead-selective electrode based on 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetrakis-(diphenylphosphinoylmethoxy)calix[4]arene (1) as an ionophore is reported. The plasticized PVC membrane containing 30% PVC, 57% ortho-nitrophenyloctylether (NPOE), 4% sodium tetraphenylborate (NaTPB) and 9% ionophore 1 was directly coated on a graphite electrode. It exhibits a nearly Nernstia...
متن کاملNovel ZrO2 ion-selective electrode based on 4,7,13,16,21,24-hexa oxa- 1,10- diazabicyc1o[8,8,8]-hexa cosane as neutral carrier in PVC matrix
In this work, a novel Zr02+ PVC-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (HODBHC) as a new ionophore is presented. The sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 M, with a near Nernstian slope of 29.9 ± 0.4 mV per decade in an acidic solution(pH=1). The limit of detection is 8.0 x 1 0 7 M. The electrodes possess adv...
متن کاملNew Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions
A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...
متن کاملA Polymeric Membrane Electrode Based on p-tert-butyl- thiacalix[4]arene Derivative for Thorium Determination
The aim of this study was to construct and characterize an ion selective electrode for the potentiometric determination of thorium ions. On hand study we introduced a new calixarene molecule p-tert-butyl-thiacalix[4]arene derivative as ionophore for thorium(IV) selective polymeric membrane electrode. Due to the decisive role of solvent mediators, we fabricated membranes with the plasticizers DB...
متن کاملComparative study of the response of membrane electrodes based on calix[6]arene and calix[8]arene derivatives to organic ammonium ions.
p-tert-Butylcalix[8]arene-octaacetic acid octaethyl ester and calix[8]arene-octaacetic acid octaethyl ester well recognized 2-phenylethylamine and phenylalanine methyl ester compared with the corresponding calix[6]arene derivatives. Moreover, the calix[8]arene derivatives, especially one having tert-butyl groups, gave better selectivity against biologically active amines having a complicated st...
متن کامل