Relation of age to isoenzyme pattern and total activity of amylase in serum.

نویسندگان

  • P J Bossuyt
  • R Van den Bogaert
  • S L Scharpé
  • Y Van Maercke
چکیده

Pancreatic and salivary isoenzymes of amylase were determined in serum from 70 subjects. Thin-layer gel/isoelectric focusing was used to separate the isoenzymes. Because other studies (J. Lab. Clin. Med. 90: 141-151, 1977) show that the major isoamylases have isoelectric points between 5.8 and 7.2, we focused the sera on polyacrylamide gel plates with a pH gradient from 5.5 to 8.5. The separated amylase fractions were made visible by direct incubation with a commercially available dye-starch polymer. Isoelectric focusing proved to be convenient, precise, and reproducible, and it can be used as a routine analysis to detect even slight changes in serum amylase distributions. We found that the isoamylase distribution is age dependent, whereas total amylase activity shows no correlation with age.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Lipase and total amylase and its isoenzymes as markers of pancreatic injury in patients treated with antiepileptic drugs].

OBJECTIVE The study of the serum lipase and total amylase and its isoenzymes as biochemical markers of pancreatic injury in patients treated with valproic acid and other enzyme-inducing antiepileptic drugs. METHOD The serum activities of lipase and total amylase and its isoenzymes were determined in 41 patients treated in monotherapy with valproic acid, 50 patients in mono/polytherapy with ph...

متن کامل

Reference intervals for amylase isoenzymes in serum and plasma of infants and children.

Measurement of pancreatic (P) and salivary-like (S) amylase isoenzyme activity in serum of adults is useful as an indirect indicator of pancreatic and salivary gland exocrine dysfunction. To extend the use of this assay to the pediatric population, we measured amylase isoenzymes in 546 serum and plasma samples and defined normal reference intervals for the P and S isoenzymes as a function of ag...

متن کامل

Electrophoretic pattern of amylase isoenzymes in serum and urine of normal persons.

We separated and measured amylase isoenzymes in the serum and urine of 3036 normal persons by electrophoresis on a thin layer of polyacrylamide gel. We wished to establish the normal pattern of these isoenzymes and to evaluate the usefulness of this method of electrophoresis in clinical diagnosis. Results for patients with hyper- or hypofunctioning pancreas and salivary glands suggested that es...

متن کامل

Efficiencyin the Diagnosisof Acute PancreatitisIncreasedby Improved Electrophoresisof Amylase lsoenzymeP3on CelluloseAcetate

Serum from patients who have suffered acute pancreatitis contains P3, an isoenzyme of pancreatic-derived amylase (EC 3.2.1.1). Heretofore, complete resolution of P3 from the major salivary isoenZyme in serum, Si, has not been possible, thus compromising the diagnostic potential of P3 for pancreatitis. I describe an electrophoretic method for the essentially complete resolution of P3 from S1 by ...

متن کامل

Methods compared for determining total amylase activity and amylase isoenzymes in serum.

We evaluated two kinetic methods for determining total amylase activity and isoenzyme composition in serum. Stability studies of reagents for measuring total activity indicate that reagents containing 4-nitrophenyl-alpha-glucosides or enzyme-linked reagents can be stored only for seven days at 4 degrees C. Methods based on 4-nitrophenyl-alpha-glucoside substrates cannot be used if the reagent a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 1981