Evaluation of patient DVH‐based QA metrics for prostate VMAT: correlation between accuracy of estimated 3D patient dose and magnitude of MLC misalignment

نویسندگان

  • Noriyuki Kadoya
  • Masahide Saito
  • Makoto Ogasawara
  • Yukio Fujita
  • Kengo Ito
  • Kiyokazu Sato
  • Kazuma Kishi
  • Suguru Dobashi
  • Ken Takeda
  • Keiichi Jingu
چکیده

The purpose of this study was to evaluate the accuracy of commercially available software, using patient DVH-based QA metrics, by investigating the correlation between estimated 3D patient dose and magnitude of MLC misalignments. We tested 3DVH software with an ArcCHECK. Two different calculating modes of ArcCHECK Planned Dose Perturbation (ACPDP) were used: "Normal Sensitivity" and "High Sensitivity". Ten prostate cancer patients treated with hypofractionated VMAT (67.6 Gy/26 Fr) in our hospital were studied. For the baseline plan, we induced MLC errors (-0.75, -0.5, -0.25, 0.25, 0.5, and 0.75 mm for each single bank). We calculated the dose differences between the ACPDP dose with error and TPS dose with error using gamma passing rates and using DVH-based QA metrics. The correlations between dose estimation error and MLC position error varied with each structure and metric. A comparison using 1%/1 mm gamma index showed that the larger was the MLC error-induced, the worse were the gamma passing rates. Slopes of linear fit to dose estimation error versus MLC position error for mean dose and D95 to the PTV were 1.76 and 1.40% mm-1, respectively, for "Normal Sensitivity", and -0.53 and -0.88% mm-1, respectively, for "High Sensitivity", showing better accuracy for "High Sensitivity" than "Normal Sensitivity". On the other hand, the slopes for mean dose to the rectum and bladder, V35 to the rectum and bladder and V55 to the rectum and bladder, were -1.00, -0.55, -2.56, -1.25, -3.53, and -1.85%mm-1, respectively, for "Normal Sensitivity", and -2.89, -2.39, -4.54, -3.12, -6.24, and -4.11% mm-1, respectively, for "High Sensitivity", showing significant better accuracy for "Normal Sensitivity" than "High Sensitivity". Our results showed that 3DVH had some residual error for both sensitivities. Furthermore, we found that "Normal Sensitivity" might have better accuracy for the DVH metric for the PTV and that "High Sensitivity" might have better accuracy for DVH metrics for the rectum and bladder. We must be willing to tolerate this residual error in clinical care.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Accuracy of one algorithm used to modify a planned DVH with data from actual dose delivery

Detection and accurate quantification of treatment delivery errors is important in radiation therapy. This study aims to evaluate the accuracy of DVH based QA in quantifying delivery errors. Eighteen previously treated VMAT plans (prostate, H&N, and brain) were randomly chosen for this study. Conventional IMRT delivery QA was done with the ArcCHECK diode detector for error-free plans and plans ...

متن کامل

Correlation of phantom‐based and log file patient‐specific QA with complexity scores for VMAT

The motivation for this study was to reduce physics workload relating to patient- specific quality assurance (QA). VMAT plan delivery accuracy was determined from analysis of pre- and on-treatment trajectory log files and phantom-based ionization chamber array measurements. The correlation in this combination of measurements for patient-specific QA was investigated. The relationship between del...

متن کامل

Individual volume‐based 3D gamma indices for pretreatment VMAT QA

Although gamma analysis is still a widely accepted quantitative tool to analyze and report patient-specific QA for intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), the correlation between the 2D percentage gamma passing rate (%GP), and the clinical dosimetric difference for IMRT and VMAT has been questioned. The purpose of this study was to investigate the fe...

متن کامل

Comparison of DVH‐based plan verification methods for VMAT: ArcCHECK‐3DVH system and dynalog‐based dose reconstruction

The purpose of this study was comparing dose-volume histogram (DVH)-based plan verification methods for volumetric modulated arc therapy (VMAT) pretreatment QA. We evaluated two 3D dose reconstruction systems: ArcCHECK-3DVH system (Sun Nuclear corp.) and Varian dynalog-based dose reconstruction (DBDR) system, developed in-house. Fifteen prostate cancer patients (67.6 Gy/26 Fr), four head and ne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015