Patient's specific integration of OAR doses (D2 cc) from EBRT and 3D image‐guided brachytherapy for cervical cancer
نویسندگان
چکیده
The objective of this study was to assess the recommended DVH parameter (e.g., D2 cc) addition method used for combining EBRT and HDR plans, against a reference dataset generated from an EQD2-based DVH addition method. A revised DVH parameter addition method using EBRT DVH parameters derived from each patient's plan was proposed and also compared with the reference dataset. Thirty-one biopsy-proven cervical cancer patients who received EBRT and HDR brachytherapy were retrospectively analyzed. A parametrial and/or paraaortic EBRT boost were clinically performed on 13 patients. Ten IMRT and 21 3DCRT plans were determined. Two different HDR techniques for each HDR plan were analyzed. Overall D2 cc and D0.1 cc OAR doses in EQD2 were statistically analyzed for three different DVH parameter addition methods: a currently recommended method, a proposed revised method, and a reference DVH addition method. The overall D2 ccEQD2 values for all rectum, bladder, and sigmoid for a conformal, volume optimization HDR plan generated using the current DVH parameter addition method were significantly underestimated on average -5 to -8% when compared to the values obtained from the reference DVH addition technique (P < 0.01). The revised DVH parameter addition method did not present statistical differences with the reference technique (P > 0.099). When PM boosts were considered, there was an even greater average underestimation of -8~-10% for overall OAR doses of conformal HDR plans when using the current DVH parameter addition technique as compared to the revised DVH parameter addition. No statistically significant differences were found between the 3DCRT and IMRT techniques (P > 0.3148). It is recommended that the overall D2 cc EBRT doses are obtained from each patient's EBRT plan.
منابع مشابه
Evaluation of deformable image registration in HDR gynecological brachytherapy
Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...
متن کاملMapping of dose distribution from IMRT onto MRI-guided high dose rate brachytherapy using deformable image registration for cervical cancer treatments: preliminary study with commercially available software
PURPOSE For patients undergoing external beam radiation therapy (EBRT) and brachytherapy, recommendations for target doses and constraints are based on calculation of the equivalent dose in 2 Gy fractions (EQD2) from each phase. At present, the EBRT dose distribution is assumed to be uniform throughout the pelvis. We performed a preliminary study to determine whether deformable dose distributio...
متن کاملComparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
BACKGROUND To compare intracavitary brachytherapy (ICBT) planning methods for cervical cancer, based on either orthogonal radiographs (conventional plan) or CT sections (CT plan); the comparison focused on target volume coverage and dose volume analysis of organs at risk (OARs), by representing point doses defined by the International Commission on Radiation Units and Measurement (ICRU) and dos...
متن کاملThe adoption of 3D image-guided brachytherapy for cervical carcinoma is gaining momentum in Southeast Asia and heading north
During 3D IGBT, MRI images are used to contour the tumor and surrounding organs-at-risk (OAR), enabling highly accurate planning of sufficient radiation doses to better treat the tumor. At the same time, doses to OARs, such as the bladder and rectum, are reduced (figures 2-4). Despite these benefits to the patient, the adoption of 3D IGBT for cervical carcinoma is slow in Southeast Asia, but is...
متن کاملOut-Of-Field Dose Measurement and Second Cancer-Risk Estimation Following External Beam Radiotherapy and Brachytherapy for Cervical Cancer Treatment: A Phantom Study
Introduction: The present study aimed to measure the scatter and leakage dose received by out-of-field organs while delivering Radiotherapy (RT) treatment of cervical cancer. Moreover, this study estimated the risk of second cancer (SC). The doses to out-of-field organs were measured using a lithium fluoride (TLD 100) dosimeter while delivering External Beam Radiothera...
متن کامل