Pulsed dose rate brachytherapy – is it the right way?
نویسنده
چکیده
Pulsed dose rate (PDR-BT) treatment is a brachytherapy modality that combines physical advantages of high-dose-rate (HDR-BT) technology (isodose optimization, radiation safety) with the radiobiological advantages of low-dose-rate (LDR-BT) brachytherapy. Pulsed brachytherapy consists of using stronger radiation source than for LDR-BT and producing series of short exposures of 10 to 30 minutes in every hour to approximately the same total dose in the same overall time as with the LDR-BT. Modern afterloading equipment offers certain advantages over interstitial or intracavitary insertion of separate needles, tubes, seeds or wires. Isodose volumes in tissues can be created flexibly by a combination of careful placement of the catheter and the adjustment of the dwell times of the computerized stepping source. Automatic removal of the radiation sources into a shielded safe eliminates radiation exposures to staff and visitors. Radiation exposure is also eliminated to the staff who formerly loaded and unloaded multiplicity of radioactive sources into the catheters, ovoids, tubes etc. This review based on summarized clinical investigations, analyses the feasibility and the background to introduce this brachytherapy technique and chosen clinical applications of PDR-BT.
منابع مشابه
Calculation of absorbed dose rate in the lungs, ribs and skin by the mammosite applicator in breast cancer brachytherapy with MCNP
Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...
متن کاملProof of Symmetric Dose Distribution in Mammosite Applicator in Breast Brachytherapy with MCNP Simulation
Introduction: In brachytherapy treatments, high-dose sources are used in interstitial placement. In this paper, the modeling of a common breast cancer treatment applicator called MammoSite is done by the Monte Carlo simulation code. Then, to study and calculate the amount of doses in the breast and the dose rate of the organs at risk of radiation, including: lungs, ribs and ski...
متن کاملPulsed Dose Rate Brachytherapy – Description of a Method and a Review of Clinical Appli- Cations
Pulsed Dose Rate (PDR) treatment is a new brachytherapy modality that combines physical advantages of high-dose-rate (HDR) technology (isodose optimization and radiation safety) with radiobiological advantages of low-dose-rate (LDR) brachytherapy. Pulsed brachytherapy uses a stronger radiation source than that employed in LDR brachytherapy and provides a series of short 10 to 30 minutes long ex...
متن کاملThromboembolic events following brachytherapy: case reports
Pulsed-dose-rate (PDR) brachytherapy is a recent brachytherapy modality combining the radiobiological advantages of low-dose-rate (LDR) brachytherapy with increased possibilities of dose optimization and radiation safety. However, treatment duration remains protracted, as the prescribed dose is typically delivered through pulses that do not exceed 0.5 Gy/h for critical organs. It is frequently ...
متن کاملRadiation biology in brachytherapy.
The biological rationale for the use of brachytherapy, which is undergoing a significant resurgence in the United States, is reviewed with emphasis on low dose rate (LDR brachytherapy). Some of the newer alternatives that have recently been developed, such as pulsed dose rate (PDR) brachytherapy, are discussed.
متن کامل