Ultrasound-guided retrieval of lost intrauterine devices using very fine grasping forceps: a case series.
نویسندگان
چکیده
AIM To assess the efficacy of a novel ultrasound-guided procedure for the retrieval of intrauterine contraceptive devices (IUDs) when the threads are not visible at the external cervical os ('lost threads'). METHODS This was a prospective cohort study of consecutive women referred for ultrasound examination because of lost IUD threads. The procedures were performed under local anaesthesia in the outpatient setting. After injection of local anaesthetic, the anterior cervical lip was grasped with a vulsellum forceps. A 5Fr hysteroscopy grasping forceps was introduced transcervically into the uterine cavity under continuous transabdominal ultrasound guidance. The IUD was then grasped and removed from the uterus. Patients' demographic data, gynaecological history, ultrasound findings, duration of procedure, success rate and pain score were recorded. RESULTS Twenty-three consecutive women were included in the study. Ultrasound examination showed an IUD correctly sited in the centre of the uterine cavity in 20/23 (87%), in 2/23 (9%) it was partially embedded in the myometrium and in 1/23 (4%) the IUD was partially sited in the cervical canal. In 8/23 (35%) women the IUD threads were not visible on ultrasound scan. Removal of the IUD was successful in 22/23 (96%) cases with a median operating time of 3 (interquartile range 1.25-4.75) minutes. 15/23 (65%) women experienced no or minimal pain (pain score ≤3), 4/23 (17%) reported moderate pain (pain score 4-6) and 4/23 (17%) described the pain as severe (pain score 7-10). No complications were recorded during or immediately after the procedure. CONCLUSIONS Ultrasound-guided retrieval of lost IUDs using fine hysteroscopy grasping forceps is a highly successful technique and is well tolerated by women.
منابع مشابه
P-70: Ultrasound Guided Artificial Insemination:A Randomized Controlled Trial
Background: To ascertain whether using ultrasound guidance during intrauterine insemination (IUI) could increase pregnancy rates. Materials and Methods: The population under study consisted of 73 consecutive couples subjected to IUI in our Human Reproduction Unit, between September and December 2006, with a total of 231 IUI cycles performed. The patients were randomized using a computer-generat...
متن کاملThe Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report
Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...
متن کاملManagement of a cervical heterotopic pregnancy presenting with first-trimester bleeding: case report and review of the literature.
OBJECTIVE To report a rare case of a cervical heterotopic pregnancy resulting from intrauterine insemination (IUI) that presented with first-trimester bleeding. DESIGN Case report and literature review. SETTING Large university-affiliated infertility practice. PATIENT(S) A 40-year-old gravida 2 para 1 Asian woman at 7-3/7 weeks gestational age following clomiphene citrate/IUI for the trea...
متن کاملASIAN EUS CUP: Asian EUS Cup-03: Endoscopic ultrasound-guided biliary drainage with misplaced antegrade stent-repositioned with forceps through obstetric anal sphincter injuries
S42 ENDOSCOPIC ULTRASOUND / VOLUME 6 / SUPPLEMENT 1 / AUGUST 2017 Asian EUS Cup-01 Endoscopic ultrasound-guided fine needle aspiration cytology from unusual locations Rajesh Puri, Narendra S. Choudhary, Rinkesh K.
متن کاملO-39: Ultrasound Deformable Model for Virtual Surgery Simulation of Oocyte Retrieval in Infertility Programs
Background The use of a medical simulator should enhance the goals of minimally invasive surgery: patient safety, cosmesis, shortening the length of hospital admissions, and reducing cost. Using an innovative approach to the handling of ultrasound images in virtual reality simulation, this article describes a process that employs a hybrid model of deformable models that can be applied in the te...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of family planning and reproductive health care
دوره 41 4 شماره
صفحات -
تاریخ انتشار 2015