Monte Carlo calculation of the TG-43 dosimetric parameters of a new BEBIG Ir-192 HDR source.

نویسندگان

  • Domingo Granero
  • José Pérez-Calatayud
  • Facundo Ballester
چکیده

BACKGROUND AND PURPOSE High dose rate (HDR) brachytherapy is a highly extended practice in clinical brachytherapy today. Quality dose rate distribution datasets of the HDR sources used in a clinical treatment are required. Because of the different source designs, a specific dosimetry dataset is required for each source model. In the recently published BRAPHYQS-ESTRO Report, an overview of available dosimetric data for all HDR Ir-192 sources is given, pointing out the lack of data for one of the sources that is used by the BEBIG MultiSource afterloading system (BEBIG GmbH, Germany). The purpose of this study is to obtain detailed dose rate distributions in liquid water media around this source. MATERIAL AND METHODS The Monte Carlo code GEANT4 was used to estimate dose rate in water and air-kerma strength around the Ir-192 source. All the details of the stainless steel encapsulated BEBIG HDR 1.1mm in external diameter has been included in the simulation. RESULTS A complete dosimetric dataset for the BEBIG Ir-192 HDR source is presented. TG43 dosimetric functions and parameters have been obtained as well as a 2D rectangular dose rate table, consistent with the TG43 dose calculation formalism. The dosimetric parameters and functions obtained for the BEBIG HDR source have been compared with that obtained in the literature for others HDR sources, showing that the use of specific datasets for this new source is justified. CONCLUSIONS This dataset can be used as input in the TPS and to validate its calculations. As policy of BRAPHYQS-ESTRO task group, this dataset will be incorporated to the website: available to users in excel format.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Dosimetric characteristics of a New 192Ir-PDR Brachytherapy Source According to AAPM TG- 43 Protocol using Monte Carlo simulation technique

Introduction: 192Ir is one of the important sources frequently used in brachytherapy. Up to now, a lot of commercial models of this source have been made which Ir-192 has been recently added to them. The aim of the present study is to determine the dosimetric parameters of this new source model based on the recommendations of TG-43(U1) protocol using Monte Carlo simulation tech...

متن کامل

Monte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom

Theoretical and experimental studies have been applied for dosimetric parameters determination of the brachytherapy sources (1-3). Usually, Monte Carlo method has been used to define such quantities as the anisotropy dose function, the radial dose function, and the dose calculation close to the source in brachytherapy (4-6). Ir source is used widely in brachytherapy to treat localized tumors ne...

متن کامل

Determination of TG-43 Dosimetric Parameters for Photon Emitting Brachytherapy Sources

Objective: Brachytherapy sources are widely used for the treatment of cancer. The report of Task Group No. 43 (TG-43) of American Association of Physicists in Medicine is known as the most common method for the determination of dosimetric parameters for brachytherapy sources. The aim of this study is to obtain TG-43 dosimetric parameters for 60Co, 137Cs, 192Ir and 103Pd brachyt...

متن کامل

Monte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom

Background: Monte Carlo and experimental relative dose determination in a water phantom, due to a high dose rate (HDR) 192Ir source is presented for real energy spectrum and monochromatic at 356 keV. Materials and Methods: The dose distribution has been calculated around the 192Ir located in the center of 30 cm ×30 cm ×30 cm water phantom using MCNP4C code by Monte Carlo method. Relati...

متن کامل

Accuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code

Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

دوره 76 1  شماره 

صفحات  -

تاریخ انتشار 2005