Identification of ubiquinones and menaquinones in activated sludge by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

نویسندگان

  • Meng-chun Gao
  • Min Yang
  • Jian-ying Hu
  • Bing Shao
  • Hai-feng Zhang
  • Hong-yan Li
چکیده

A sensitive analytical method has been developed for identification of ubiquinones (UQ-n(Hx)) and menaquinones (MK-n(Hx)) in activated sludge by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry in negative mode (LC-NI-APCI-MS). Extraction and clean-up of samples were carried out on Sep-Pak Plus Silica solid-phase extraction cartridges. Complete separation of quinones was achieved with an ODS analytical column and using isopropyl ether-methanol (17:83, v/v) as the mobile phase. The compositions of ubiquinones and menaquinones were determined directly using combined information on retention time, the molecular ion mass and fragment ion masses. The lowest instrument quantitative detection limits (LODinst) for UQ-6, UQ-10, and Vitamin K1 were estimated to be 0.4, 4 and 0.12 ng (S/N = 10) using LC-NI-APCI-MS in SIM mode, and the lowest method detection limits (LODmeth) achieved by spiking experiment were estimated to be 0.2, 2 and 0.06 microg/g for UQ-6, UQ-10 and Vitamin K1, respectively. On the other hand, the LODinst for UQ-6, UQ-10, and Vitamin K1 were estimated to be 10, 100 and 2 ng (S/N = 10) using LC-NI-APCI-MS in full-scan mode, and the LODmeth were estimated to be 7, 60 and 1.2 microg/g for UQ-6, UQ-10, and Vitamin K1, respectively. Both LC-NI-APCI-MS and LC-UV/DAD were applied in the analysis of an activated sludge extract. UQ-n (n = 6-10), MK-n (n = 6-10), MK-n(H2) (n = 7-10), MK-n(H4) (n = 8-9) and MK-8(H6) were detected by LC-NI-APCI-MS, while UQ-6, UQ-7, MK-7(H), MK-9 and MK-10(H2) were not found by LC-UV/DAD. These results suggest that LC-NI-APCI-MS is more sensitive than LC-UV/DAD for the analysis of quinones in environmental samples such as sediment, activated sludge and bio-film in biological processes and other aquatic environments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of very long chain polyunsaturated fatty acids using high-performance liquid chromatography - atmospheric pressure chemical ionization mass spectrometry.

The presence and identity of very long chain polyunsaturated fatty acids from three freshwater crustacean species, Bathynella natans, B. baicalensis and Baicalobathynella magna from Lake Baikal and caves of central Europe were determined by means of liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization (LC-MS with APCI). LC-MS with APCI enabled the identification...

متن کامل

Integration of ion-exchange chromatography fractionation with reversed-phase liquid chromatography-atmospheric pressure chemical ionization mass spectrometer and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for isolation and identification of compounds in Psoralea corylifolia.

An approach for the separation and identification of components in a traditional Chinese medicine Psoralea corylifolia was developed. Ion-exchange chromatography (IEC) was applied for the fractionation of P. corylifolia extract, and then followed by concentration of all the fractions with rotary vacuum evaporator. Each of the enriched fractions was then further separated on an ODS column with d...

متن کامل

Analysis of Polymer Additives and Impurities by Liquid Chromatography/Mass Spectrometry and Capillary Electrophoresis/Mass Spectrometry

The analysis of polymeric materials can be quite challenging because such samples are often of complex nature due to the presence of various groups of additives, compounding ingredients, and fillers. Of special importance are stabilizers that protect the material from degradation by thermal stress during manufacture or from environmental impact during use. Apart from intact stabilizers, the deg...

متن کامل

Separation and identification of corticosterone metabolites by liquid chromatography--electrospray ionization mass spectrometry.

High-performance liquid chromatography coupled to atmospheric pressure ionization-electrospray ionization mass spectrometry (API-ESI-MS) was investigated for the analysis of corticosterone metabolites; their characterization was obtained by combining the separation on Zorbax Eclipse XDB C18 column (eluted with a methanol-water-acetic acid gradient) with identification using positive ion mode AP...

متن کامل

Liquid chromatography/atmospheric pressure ionization-mass spectrometry in drug metabolism studies.

The study of the metabolic fate of drugs is an essential and important part of the drug development process. The analysis of metabolites is a challenging task and several different analytical methods have been used in these studies. However, after the introduction of the atmospheric pressure ionization (API) technique, electrospray and atmospheric pressure chemical ionization, liquid chromatogr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1007 1-2  شماره 

صفحات  -

تاریخ انتشار 2003