Dosimetric impact of cylinder size in high‐dose rate vaginal cuff brachytherapy (VCBT) for primary endometrial cancer

نویسندگان

  • Hualin Zhang
  • Mahesh Gopalakrishnan
  • Plato Lee
  • Zhuang Kang
  • Vythialingam Sathiaseelan
چکیده

The purpose of this study was to evaluate the dosimetric impact of cylinder size in high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT). Sample plans of HDR VCBT in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm incre-ment were created and analyzed. The doses were prescribed either at the 0.5cm depth with 5.5 Gy for 4 fractions or at the cylinder surface with 8.8 Gy for 4 frac-tions, in various treatment lengths. A 0.5 cm shell volume called PTV_Eval was contoured for each plan and served as the target volume for dosimetric evaluation. The cumulative and differential dose volume histograms (c-DVH and d-DVH), mean doses (D-mean) and the doses covering 90% (D90), 10% (D10), and 5% (D5) of PTV_Eval were calculated. In the 0.5 cm depth regimen, the DVH curves were found to have shifted toward the lower dose zone when a larger cylinder was used, but in the surface regimen the DVH curves shifted toward the higher dose zone as the cylinder size increased. The D-means of the both regimens were between 6.9 and 7.8 Gy and dependent on the cylinder size but independent of the treatment length. A 0.5 cm variation of diameter could result in a 4% change of D-mean. Average D90s were 5.7 (ranging from 5.6 to 5.8 Gy) and 6.1 Gy (from 5.7 to 6.4 Gy), respectively, for the 0.5 cm and surface regimens. Average D10 and D5 were 9.2 and 11 Gy, respectively, for the 0.5 cm depth regimen, and 8.9 and 9.7 Gy, respectively, for the surface regimen. D-mean, D90, D10, and D5 for other prescription doses could be calculated from the lookup tables of this study. Results indicated that the cylinder size has moderate dosimetric impact, and that both regimens are comparable in dosimetric quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of air pockets in high-dose-rate vaginal cuff brachytherapy using cylindrical applicators

PURPOSE To retrospectively assess the incidence and magnitude of air pockets around vaginal cylinders and its impact on dose distribution in vaginal cuff image-guided high-dose-rate (HDR) brachytherapy. MATERIAL AND METHODS Fifty endometrial carcinoma patients treated by postoperative HDR vaginal cuff brachytherapy were included in the study. The average age of patients was 58.3 ± 11.8 years ...

متن کامل

Single versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning

PURPOSE To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. MATERIAL AND METHODS We randomly selected 12 patients with endometrial carcinoma, who received adjuvant vaginal cuff ...

متن کامل

Effects of vaginal cylinder position on dose distribution in patients with endometrial carcinoma in treatment of vaginal cuff brachytherapy

PURPOSE To investigate the impact of different cylinder positions on dosimetry of critical structures in patients with endometrial carcinoma undergoing three-dimensional image-based vaginal cuff brachytherapy (VCB). MATERIAL AND METHODS We delivered VCB at a dose of 4 Gy to a depth of 5 mm in the vaginal cuff of 15 patients using three different cylinder positions (neutral [N], parallel [P], ...

متن کامل

Bladder and rectum dose estimations on digitized radiographs for vaginal brachytherapy after hysterectomy

The purpose of this study was to evaluate the feasibility of assessing bladder and rectal point doses, using orthogonal radiographs without treatment planning, for vaginal cylinder applicator (VC), high-dose-rate (HDR) vaginal cuff brachytherapy (BT) after hysterectomy. Thirty-three VC HDR BT treatment plans from 31 postop- erative endometrial cancer patients were retrospectively analyzed. Sing...

متن کامل

An analysis of simulation for adjuvant intracavitary high-dose-rate brachytherapy in early-stage endometrial cancer.

PURPOSE The utility of serial simulations in vaginal vault irradiation is controversial. Our primary endpoint was to assess the significance of simulation in women who received adjuvant intracavitary high-dose-rate brachytherapy (HDR-BT) for early-stage endometrial adenocarcinoma. Secondary endpoints included assessment of acute and late treatment toxicity, medication requirements, and charges ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016