Botanical Trash Mixtures Analyzed with Near-Infrared and Attenuated Total Reflectance Fourier Transform Spectroscopy and Thermogravimetric Analysis

نویسندگان

  • Chanel Fortier
  • James Rodgers
  • Jonn Foulk
چکیده

Botanical cotton trash mixed with lint reduces cotton’s marketability and appearance. During cotton harvesting, ginning, and processing, trash size reduction occurs, thus complicating its removal and identification. This trash causes problems by increasing ends down in yarn formation and thus processing efficiency. The Uster® High Volume Instrument (HVI) and Shirley Analyzer are extensively used to determine trash levels in cotton lint, but they do not specifically identify its origin. This study was performed to determine the potential for recognizing differences between botanical cotton trash mixtures via near-infrared (NIR) spectroscopy and attenuated total reflectance-Fourier transform infrared (ATR/FT-IR) spectroscopy, and thermogravimetric analysis (TGA). A “proof of concept” was demonstrated that showed the promise of NIR and ATR/FT-IR spectroscopy along with TGA to be employed to identify binary mixtures of botanical cotton trash. In the case of the ATR/FTIR results, the leaf and seed coat mixtures in the presence of cotton yielded the lowest accuracy of the trash mixtures. This might have arisen from the presence of noncellulosics in the samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization and quantitation of aprepitant drug substance polymorphs by attenuated total reflectance fourier transform infrared spectroscopy.

In this study, we report the use of attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FT-IR) for the identification and quantitation of two polymorphs of Aprepitant, a substance P antagonist for chemotherapy-induced emesis. Mixtures of the polymorph pair were prepared by weight and ATR-FT-IR spectra of the powdered samples were obtained over the wavelength range of 700-1...

متن کامل

Real-Time Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy To Monitor Multiacrylate Polymerization Reactions

Real-time attenuated total reflectance-Fourier transform infrared spectroscopy was used to follow the conversion during acrylate polymerizations by measuring the presence of functional groups a t finite depths from the crystal surface. By varying the film thickness, the reactivity of multiacrylates could be spatially resolved. These results were compared to results from differential photocalori...

متن کامل

Investigation of the potential utility of single-bounce attenuated total reflectance Fourier transform infrared spectroscopy in the analysis of distilled liquors and wines.

A new Fourier transform infrared (FTIR) spectroscopic method based on single-bounce attenuated total reflectance (SB-ATR) spectroscopy was developed for the analysis of distilled liquors and wines. For distilled liquors, a partial least-squares (PLS) calibration was developed for alcohol determination based on the SB-ATR/FTIR spectra of mixtures of ethanol and distilled water. An independent se...

متن کامل

A simple method for the quantification of molecular decorations on silica particles

A simple, rapid quantitative approach to determining attachment density on silica nanoparticles has been demonstrated using attenuated total reflectance Fourier transform infrared spectroscopy and verified by thermogravimetric analysis. A very high attachment of approximately 5 attachments per nm2 has been achieved through photoinduced thiol-ene click reaction of 11-bromo-1-undecene with a thio...

متن کامل

Rapid determination of fecal fat by Fourier transform infrared analysis (FTIR) with partial least-squares regression and an attenuated total reflectance accessory.

Fecal lipid content is usually determined by titrimetric or gravimetric methods, but these methods are time consuming and involve dangerous solvents. We have developed a new method of measuring fecal lipids by Fourier transform infrared spectrometry (FTIR) with an attenuated total reflectance accessory that is fast and requires no solvents. The spectra of stools from 4000 to 750 cm-1 were analy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015