Impact of Low Filter Resistances on Subjective and Physiological Responses to Filtering Facepiece Respirators
نویسندگان
چکیده
Ten subjects underwent treadmill exercise at 5.6 km/h over one hour while wearing each of three identical appearing, cup-shaped, prototype filtering facepiece respirators that differed only in their filter resistances (3 mm, 6 mm, and 9 mm H2O pressure drop). There were no statistically significant differences between filtering facepiece respirators with respect to impact on physiological parameters (i.e., heart rate, respiratory rate, oxygen saturation, transcutaneous carbon dioxide levels, tympanic membrane temperature), pulmonary function variables (i.e., tidal volume, respiratory rate, volume of carbon dioxide production, oxygen consumption, or ventilation), and subjective ratings (i.e., exertion, thermal comfort, inspiratory effort, expiratory effort and overall breathing comfort). The nominal filter resistances of the prototype filtering facepiece respirators correspond to airflow resistances ranging from 2.1 - 6.6 mm H2O/L/s which are less than, or minimally equivalent to, previously reported values for the normal threshold for detection of inspiratory breathing resistance (6 - 7.6 mm H2O/L/sec). Therefore, filtering facepiece respirators with filter resistances at, or below, this level may not impact the wearer differently physiologically or subjectively from those with filter resistances only slightly above this threshold at low-moderate work rates over one hour.
منابع مشابه
Pressure Drop of Filtering Facepiece Respirators: How Low Should We Go?
INTRODUCTION This study was undertaken to determine the mean peak filter resistance to airflow (Rfilter) encountered by subjects while wearing prototype filtering facepiece respirators (PRs) with low Rfilter during nasal and oral breathing at sedentary and low-moderate work rates. MATERIAL AND METHODS In-line pressure transducer measurements of mean Rfilteracross PRs with nominal Rfilter of 2...
متن کاملA survey of respirators usage for airborne chemicals in Korea.
A questionnaire survey was undertaken to identify the current status of respirator usage in manufacturing work environments subject to gas/vapor chemicals exposure in Korea and to suggest improvements to enhance the effectiveness of respirator usage. The number of target companies included 17 big companies, 110 small & mid-size companies, and 5 foreign companies, and the number of respondents i...
متن کاملEffect of external airflow resistive load on postural and exercise-associated cardiovascular and pulmonary responses in pregnancy: a case control study
BACKGROUND Facial coverings (e.g., balaclavas, niqabs, medical/surgical masks, respirators, etc.), that impose low levels of airflow resistive loads, are worn by millions of pregnant women worldwide, but little data exist addressing their impact on pregnancy-associated cardiovascular and pulmonary responses. METHODS 16 pregnant and 16 non-pregnant women were monitored physiologically (heart r...
متن کاملEvaluation of a quantitative fit testing method for N95 filtering facepiece respirators.
A method for performing quantitative fit tests (QNFT) with N95 filtering facepiece respirators was developed by earlier investigators. The method employs a simple clamping device to allow the penetration of submicron aerosols through N95 filter media to be measured. The measured value is subtracted from total penetration, with the assumption that the remaining penetration represents faceseal le...
متن کاملFilter Performance Degradation of Electrostatic N95 and P100 Filtering Facepiece Respirators by Dioctyl Phthalate Aerosol Loading
Polydisperse dioctyl phthalate (DOP) aerosols are employed for testing filter penetration with loading of Rand P-series particulate filters for National Institute for Occupational Safety and Health (NIOSH) certification. Penetration for filters must not exceed NIOSH allowed maximum levels during the entire loading of 200 mg DOP indicating no filter degradation. Degradation of respirators loaded...
متن کامل