The Intrinsic Size of Sagittarius A* from 0.35 Cm to 6 Cm
نویسندگان
چکیده
We present new high-resolution observations of Sagittarius A* at wavelengths of 17.4 to 23.8 cm with the Very Large Array in A configuration with the Pie Town Very Long Baseline Array antenna. We use the measured sizes to calibrate the interstellar scattering law and find that the major axis size of the scattering law is smaller by ∼ 6% than previous estimates. Using the new scattering law, we are able to determine the intrinsic size of Sgr A* at wavelengths from 0.35 cm to 6 cm using existing results from the VLBA. The new law increases the intrinsic size at 0.7 cm by ∼ 20% and < 5% at 0.35 cm. The intrinsic size is 13 −3 Schwarzschild radii at 0.35 cm and is proportional to λ, where γ is in the range 1.3 to 1.7. Subject headings: Galaxy: center — galaxies: active — techniques: interferometric — scattering
منابع مشابه
Intrinsic Size of Sgr a ? : 72 Schwarzschild Radiik
Recent proper motion studies of stars at the very center of the Galaxy strongly suggest that Sagittarius (Sgr) A ? , the compact nonthermal radio source at the Galactic Center, is a 2.510 6 M black hole. By means of near-simultaneous multi-wavelength Very Long Baseline Array measurements, we determine for the rst time the intrinsic size and shape of Sgr A ? to be 72 R sc (?) by < 20 R sc (?), w...
متن کاملThe Effect of Cycocel and Pot Size on Vegetative Growth and Flowering of Zinnia (Zinnia elegans)
Zinnia is a very attractive and beautiful ornamental plant due to the diversity of color and flowering period. The effect of cycocel and pot size was studied on growth and flowering of zinnia in a factorial experiment based on a randomized complete design with two factors: cycocel at 3 levels (0, 1000 and 2000 ppm) and pot size at 4 levels (10, 12, 14 and 16 cm) with 12 treatments and 3 replica...
متن کاملThe Effect of Field Size and Distance from the Field Center on Neutron Contamination in Medical Linear Accelerator
Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many param...
متن کاملThe Effect of Field Size and Distance from the Field Center on Neutron Contamination in Medical Linear Accelerator
Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many param...
متن کاملThe Effect of Caspian Sea Water on Corrosion Resistance and Compressive Strength of Reinforced Concrete Containing Different SiO2 Pozzolan
Many parameters are influenced by the diffusion of chloride on concrete in marine environments and these can affect concrete quality. In this study, the effect of water to cement ratio of 0.35, 0.40 and 0.45 on corrosion resistance and compressive strength of reinforced concrete was evaluated. Moreover, different percentages of micro silica (SiO2) including 5, 7.5 and 10% were utilized, in orde...
متن کامل