Delayed ipsilateral parenchymal hemorrhage following flow diversion for the treatment of anterior circulation aneurysms.

نویسندگان

  • J P Cruz
  • M Chow
  • C O'Kelly
  • B Marotta
  • J Spears
  • W Montanera
  • D Fiorella
  • T Marotta
چکیده

BACKGROUND AND PURPOSE The PED is a flow-diverting stent designed for the treatment of cerebral aneurysms. We report 4 cases of delayed ipsilateral IPH following the technically successful treatment of anterior circulation aneurysms with the PED. MATERIALS AND METHODS Clinical and imaging data from all patients undergoing aneurysm treatment with the PED at 2 institutions were analyzed to assess the incidence of delayed IPH after treatment with the PED. RESULTS A total of 66 patients (47 anterior circulation) with cerebral aneurysms underwent treatment with a PED between January 2008 and November 2010. Four patients experienced delayed periprocedural IPH, all after the treatment of anterior circulation aneurysms (8.5%, 4/47). The aneurysm size ranged from 5 to 21 mm. All IPHs occurred within the cerebral hemisphere, ipsilateral to the treated aneurysm, and were anatomically remote from the treated aneurysms. All procedures were uncomplicated, and patients emerged from general anesthesia at neurologic baseline. The hemorrhages became clinically evident between 1 and 6 days after the procedure. Two patients had unfavorable outcomes (mRS scores, 4 and 6). CONCLUSIONS Delayed IPH may occur after the treatment of anterior circulation aneurysms with flow diverters. This complication does not seem to be restricted to a specific aneurysm subtype and does not seem to be related to an intraprocedural complication or solely attributable to DAT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The eJournal of the European Society of Minimally Invasive Neurological Therapy The ESMINT Retrospective Analysis of Delayed Aneurysm Ruptures after flow diversion (RADAR) study

Introduction: Rupture following flow diversion treatment has been reported as a complication of this technique. The aim of this survey was to investigate the efficacy of flow diversion by retrospectively analysing the rate of delayed ruptures in all centres using this technology. Methods: A questionnaire based survey about thromboembolic and haemorrhagic complications related to flow diversion ...

متن کامل

یافته های آنژیوگرافی در آنوریسم داخل جمجمه ای، بیمارستان امام، 79-1374

Background: This investigation was conducted in order to study angiographic findings in patients with cerebral aneurysm. Materials and Methods: The study conducted on 136 cases of ruptured cerebral aneurysms between 1995-2000 confirmed by means of 4-vessel cerebral angiography to get an insight to racial, geographic and environmental factors predisposing to the occurrence of subarachnoid hemorr...

متن کامل

Revisiting the risk of intraparenchymal hemorrhage following aneurysm treatment by flow diversion.

following Aneurysm Treatment by Flow Diversion We read with interest the recent case series by Cruz et al, reporting their experience with the Pipeline Embolization Device (PED; Chestnut Medical Technologies, Menlo Park, California) in 66 patients with 47 anterior circulation aneurysms. The emphasis of this article was on the high rate of delayed (1– 6 days postprocedure) ipsilateral intraparen...

متن کامل

Delayed Ischemic Stroke after Flow Diversion of Large Posterior Communicating Artery Aneurysm

For securing large, giant, and wide-neck aneurysms, conventional coil embolization has substantial limitations, such as incomplete occlusion, recanalization, and a high recurrence rate. To overcome these limitations, a novel paradigm was suggested and, as a result, flow-diverting device was developed. The flow-diverting device is an innovative and effective technique to allow securing of large,...

متن کامل

Redefining Onyx HD 500 in the Flow Diversion Era

We report the largest US case series results using Onyx HD-500 (EV3), a new liquid embolic agent, in the successful treatment of 21 patients with wide-neck intracranial aneurysms (mean size 4.5 mm), which are at increased risk of incomplete occlusion or recanalization with standard endovascular intervention utilizing detachable platinum coils. All aneurysms were located in the anterior circulat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 33 4  شماره 

صفحات  -

تاریخ انتشار 2012