Padronização do potencial evocado auditivo de tronco encefálico utilizando um novo equipamento***** Standardization of brainstem auditory evoked potential using a new device

نویسندگان

  • Ilka do Amaral Soares
  • Pedro de Lemos Menezes
  • Aline Tenório Lins Carnaúba
  • Liliane Desgualdo Pereira
چکیده

Background: standardization of Brainstem Auditory Evoked Potential (BAEP) using a new device. Aim: to standardize BAEP responses using a new device developed (NDD) in Brazil. Method: analysis of absolute latencies, interpeaks and wave amplitudes of BAEP, using a new device developed to study normal-hearing groups (91 adults) and individuals (15 adults) with bilateral neurosensory hearing loss. Responses obtained in the EP15 hearing device/Interacoustics and the NDD were compared. For this, the following paramenters were used: non-filtered click of 100 microsecond (μs), totaling 2000 stimuli in rarefied polarity, stimulation frequency of 13.1 clicks/s, intensity of 80 decibels normalized hearing level (dB nHL), with a window of 10 milliseconds and bandpass filter between 100 and 3000 Hertz (Hz). Significance level was set at 0.05. Results: absolute latency and interpeak means for 76 normal-hearing individuals with the NDD were: wave I=1.50, III=3.57, V=5.53, I-III=2.06, III-V=1.96 and I-V=4.02. When analyzing results according to gender, there was a statistically significant difference for the absolute latencies of waves III and V and in interpeaks I-III and I-V. Mean amplitude value of wave I=0.384 microvolt (μV) and of wave V=0.825 μV. There was no statistically significant difference between the absolute latencies and interpeaks of the two devices in the same individual. Conclusion: the components of BAEP with the NDD in normal-hearing subjects were similar regarding the tested ears, with statistically lower latencies in women. The BAEP latencies in the same individual with NDD were similar to those obtained with the EP15 / Interacoustics. Normal values of BAEP were obtained in normal-hearing adults.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of click and CE-chirp stimuli on Brainstem Auditory Evoked Potential recording Comparação dos estímulos clique e CE-chirp no registro do Potencial Evocado Auditivo de Tronco Encefálico

Purpose: To compare the latencies and amplitudes of wave V on the Brainstem Auditory Evoked Potential (BAEP) recording obtained with click and CE-chirp stimuli and the presence or absence of waves I, III and V in high intensities. Methods: Cross-sectional study with 12 adults with audiometric thresholds ≤15 dBHL (24 ears) and mean age of 27 years. The parameters used for the recording with both...

متن کامل

Potencial evocado auditivo de tronco encefálico com estímulo de fala***** Brainstem auditory evoked potential with speech stimulus

Background: although clinical use of the click stimulus for the evaluation of brainstem auditory function is widespread, and despite the fact that several researchers use such stimulus in studies involving human hearing, little is known about the auditory processing of complex stimuli such as speech. Aim: to characterize the findings of the Auditory Brainstem Response (ABR) performed with speec...

متن کامل

Estudo Do Efeito De Supressão No Potencial Evocado Auditivo De Tronco Encefálico***** Study of Suppression Effect in the Brainstem Auditory Evoked Potential Introduction

Background: the suppression effect with contralateral white noise observed in the brainstem auditory evoked potential can be influenced by the efferent auditory system. Aim: to evaluate the suppression effect with contralateral white noise in the Brainstem Auditory Evoked Potential of individuals with normal hearing. Methods: 25 individuals, ranging in age from 18 to 30 years, of both genders, ...

متن کامل

Potencial evocado auditivo de tronco encefálico em gerbils submetidos à isquemia e sepse

Introduction: An ischemic stroke is a clinical condition that affects thousands of people worldwide. As a result of this injury, neuronal death can be observed, and in the natural course of recovery, the individual may develop sepsis. Sepsis is a systemic inflammatory response that can lead the patient to death. To assess the clinical condition of a patient with this condition, the Auditory Bra...

متن کامل

Use of middle latency auditory evoked potentials in children: an integrative review Uso do potencial evocado auditivo de média latência em populações infantis: uma revisão integrativa

This study aimed to investigate on the literature the utility of Auditory middle latency response in children focusing on the study of the auditory system on its normal and deviant processes. The integrative review of the scientific literature consisted in the search for studies using databases such as PubMed, Scopus, and Scielo. The descriptors used for the search were: “auditory middle latenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010