Differences in the dose accuracy of insulin pens.

نویسندگان

  • Heike Hänel
  • Alexander Weise
  • Wei Sun
  • Johannes W Pfützner
  • Nicole Thomé
  • Andreas Pfützner
چکیده

BACKGROUND Modern insulin injection pens provide a convenient and accurate way for diabetes patients to inject insulin. They have widespread use among children and adults with type 1 and type 2 diabetes in the U.S. and Europe. This study compared the dosing accuracy of four commonly available insulin pens (OptiClik and SoloSTAR from sanofi-aventis, FlexPen from Novo Nordisk, and HumaPen LUXURA from Eli Lilly). METHODS The dosing accuracy was tested for all pens with 24 x 10 IU and 9 x 30 IU injection volumes to investigate whether the pens complied with the acceptable International Organization for Standardization (ISO) limits of 10% (+/- 1 IU) for 10 IU and 5% (+/- 1.5 IU) for 30 IU. The doses were each applied with a new needle strictly according to the instructions for use by the pen manufacturers. A pharmaceutical balance was used for the assessment of the applied volumes, and the results were corrected for the specific density of the insulin formulations. Four insulin pens (two each from different production lots) were used for each of the two volumes, resulting in a total of 192 doses per pen with 10 IU, and 72 doses per pen with 30 IU. RESULTS FlexPen (mean absolute percent deviation for 10 IU and 30 IU: 1.64 +/- 0.84% and 0.83 +/- 0.26%, respectively) and HumaPen LUXURA (1.10 +/- 0.20% and 0.62 +/- 0.19%; not significant versus FlexPen for both doses) were more accurate than the OptiClik (4.78 +/- 3.31% and 2.97 +/- 2.48%, p <.01) and the SoloSTAR (2.61 +/- 0.92% and 1.70 +/- 0.84%, p <.05). While 6.8% of doses were outside the ISO limit at 10 IU with OptiClik (13.9% at 30 IU), the corresponding figures were 0.5% and 4.1%, respectively, for SoloSTAR. No doses outside the ISO limits were seen with FlexPen or HumaPen LUXURA at 10 IU and only one 30 IU dose (1.4%) was outside the limit for FlexPen. CONCLUSIONS A direct head-to-head comparison of four insulin pens with a standardized protocol resulted in a more stable dosing accuracy of the FlexPen and the HumaPen LUXURA in comparison to the OptiClik and SoloSTAR. Even though all insulin delivery systems undergo rigorous testing before being approved for sale, there may be reasons to be attentive to the performance of the devices in practical use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose accuracy of the ClikSTAR, NovoPen 4, and Luxura insulin pens: results of laboratory and field studies.

BACKGROUND A high dosing accuracy is needed to maintain normal glycemia in patients with diabetes. This study investigated the dose accuracy of the commonly used reusable insulin pens ClikSTAR®, NovoPen® 4, and Luxura®. METHODS Pens were tested in a laboratory setting by one trained technician who delivered four doses of 30 U from each of 15 pens per pen model (a total of 60 doses from each p...

متن کامل

Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens

BACKGROUND To deliver insulin glargine 300 U/mL (Gla-300), the widely used SoloSTAR(®) pen has been modified to allow for accurate and precise delivery of required insulin units in one-third of the volume compared with insulin glargine 100 U/mL, while improving usability. Here we compare the accuracy and injection force of 3 disposable insulin pens: Gla-300 SoloSTAR(®), FlexPen(®), and KwikPen™...

متن کامل

Dosing Accuracy of Two Disposable Insulin Pens According to New ISO 11608-1

OBJECTIVE The aim was to compare 2 disposable insulin pens, FlexTouch® (Novo Nordisk, insulin aspart) and SoloSTAR® (Sanofi, insulin glulisine), according to new ISO 11608-1:2012 requirements for dosing accuracy. METHODS Sixty pens of each type were tested at 1, 40, and 80 U doses. Following the new ISO requirements, each dose was delivered from the front, middle, and rear one-third of the pe...

متن کامل

Analysis: desirable attributes of insulin injection pens that drive patient preference and compliance.

Insulin pens are used by approximately half of worldwide insulin users. Insulin pens have made insulin injections easier compared to traditional vial and syringe injections. In an article in this issue of Journal of Diabetes Science and Technology, Dr. Asakura discusses several important design parameters, which are considered during refillable insulin-injection pen design. Ease of cartridge re...

متن کامل

Dosing accuracy and insulin flow rate characteristics of a new disposable insulin pen, FlexTouch, compared with SoloSTAR.

BACKGROUND The introduction of the FlexTouch® (FT; Novo Nordisk; insulin aspart), a prefilled insulin pen with a spring-loaded mechanism, has created more insulin pen options. The present study compared the dosing accuracy of the FT with that of the manually operated SoloSTAR® (SS; Sanofi; insulin glulisine). The volumetric flow rate of insulin delivery with the FT was also evaluated. METHODS...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 2 3  شماره 

صفحات  -

تاریخ انتشار 2008