Capsule endoscopy is superior to small-bowel follow-through and equivalent to ileocolonoscopy in suspected Crohn's disease.
نویسندگان
چکیده
BACKGROUND & AIMS Evaluation of the small intestine for inflammation has traditionally relied on small-bowel follow-through (SBFT), but multiple studies have demonstrated its low diagnostic accuracy. Capsule endoscopy (CE) transmits high-quality images of the small intestinal mucosa; it can be used to visualize the entire length of the small bowel and much of the mucosa. We compared the diagnostic yields of CE vs SBFT in a prospective study of patients with suspected small-bowel Crohn's disease. METHODS Eighty patients with signs and/or symptoms of small-bowel Crohn's disease (age, 10-65 years) underwent CE, followed by SBFT and ileocolonoscopy. Readers were blinded to other test results. The primary outcome was the diagnostic yield for inflammatory lesions found with CE before ileocolonoscopy compared with SBFT and ileocolonoscopy. A secondary outcome was the incremental diagnostic yield of CE compared with ileocolonoscopy and CE compared with SBFT. RESULTS The combination of CE and ileocolonoscopy detected 107 of 110 inflammatory lesions (97.3%), whereas the combination of SBFT and ileocolonoscopy detected only 63 lesions (57.3%) (P < .001). The diagnostic yield of CE compared with ileocolonoscopy was not different (P = .09). The diagnostic yield was higher for CE than for SBFT (P < .001). Of the 80 patients with suspected Crohn's disease, 25 (31.3%) had the diagnosis confirmed. Eleven were diagnosed by CE findings alone and 5 by ileocolonoscopy findings alone. In the remaining 9 patients, diagnostic findings were identified by at least 2 of the 3 modalities. No diagnoses were made on the basis of SBFT findings alone. CONCLUSIONS CE was better than SBFT and equivalent to ileocolonoscopy in detecting small-bowel inflammation. Although ileocolonoscopy remains the initial diagnostic test of choice, CE is safe and can establish the diagnosis of Crohn's disease in patients when ileocolonoscopy results are negative or the terminal ileum cannot be evaluated. ClinicalTrials.gov Number: NCT00487396.
منابع مشابه
Small-bowel imaging in Crohn's disease: a prospective, blinded, 4-way comparison trial.
BACKGROUND With the introduction of new techniques to image the small bowel, there remains uncertainty about their role for diagnosing Crohn's disease. OBJECTIVE To assess the sensitivity and specificity of capsule endoscopy (CE), CT enterography (CTE), ileocolonoscopy, and small-bowel follow-through (SBFT) in the diagnosis of small bowel Crohn's disease. METHODS Prospective, blinded trial....
متن کاملSmall-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline.
This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). The Guideline was also reviewed and endorsed by the British Society of Gastroenterology (BSG). It addresses the roles of small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders. Main recommendations 1 ESGE recommends small-bowel video c...
متن کاملCurrent Clinical Indications for Small Bowel Capsule Endoscopy.
INTRODUCTION Small bowel capsule endoscopy is currently the first line diagnostic examination for many diseases affecting the small bowel. This article aims to review and critically address the current indications of small bowel capsule endoscopy in clinical practice. MATERIAL AND METHODS Bibliographic review of relevant and recent papers indexed in PubMed. RESULTS AND DISCUSSION Small bowe...
متن کاملDiagnostic accuracy of capsule endoscopy for small bowel Crohn's disease is superior to that of MR enterography or CT enterography.
BACKGROUND & AIMS Capsule endoscopy (CE) detects small bowel Crohn's disease with greater diagnostic yield than radiologic procedures, although there are concerns that CE has low specificity. We compared the sensitivity and specificity of CE, magnetic resonance imaging enterography (MRE) and computed tomography enterography (CTE) in patients with suspected or newly diagnosed Crohn's disease. ...
متن کاملTailoring Crohn's disease treatment: the impact of small bowel capsule endoscopy.
BACKGROUND AND AIMS Small bowel capsule endoscopy (SBCE) may detect proximal small bowel lesions that have been previously missed by ileocolonoscopy and small bowel imaging in patients with known ileal and/or colonic Crohn's disease (CD). We aimed to evaluate whether the therapeutic management is influenced by SBCE findings. METHODS Retrospective single center study. Inclusion of consecutive ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association
دوره 12 4 شماره
صفحات -
تاریخ انتشار 2014