Pedicle screws are widely used for instrumentation of the thoracolumbar spine. The anatomic studies performed in the last two decades, detailing the complex morphometry and three-dimensional anatomy of the thoracolumbar pedicles, have enabled the emergence of the so-called "free-hand" technique of pedicle screw placement based exclusively on anatomical parameters. However, in the thoracic spine, the benefits of pedicle screws have been tempered by its potential risks, such as, spinal canal violation, pedicle fracture, nerve root compression, and vascular lesions. Furthermore, the narrow and inconsistent shape of the thoracic pedicles, especially in spinal deformity, makes their placement technically challenging. In this article, the authors make a critical appraisal of current "state-of-art" of "free-hand" technique of pedicle instrumentation, analyzing its anatomical basis, surgical technique, present indications and limitations as well as the role of adjuvant image-guided and neurophysiological monitoring methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrospective Review on Accuracy: A Pilot Study of Robotically Guided Thoracolumbar/Sacral Pedicle Screws Versus Fluoroscopy-Guided and Computerized Tomography Stealth-Guided Screws

Introduction Pedicle screw insertion is the mainstay of thora-cic and lumbosacral posterior spinal instrumentation. However, it may be associated with complications such as screw mal-positioning. The purpose of this study was to develop a pilot study to compare the accuracy of robot-guided screw insertion versus hand-guided screw placement for spinal instrumentation. The hand-guided screws were...

متن کامل

شکست وسایل تثبیت ستون فقرات

This was a retrospective review of a consecutive series of patients with spinal disease in year 2000, who underwent posterior fusion and instrumentation with Harrington distraction and Cotrel-Dobousset system to evaluate causes of hardware failure. Many cases of clinical failure has been observed in spinal instrumentation used in spinal disorder like spondylolisthesis, fractures, deformities, …...

متن کامل

Radiological outcome of short segment posterior stabilisation and fusion in thoracolumbar spine acute fracture.

INTRODUCTION The optimal management of thoracolumbar spine fractures remains a matter of controversy. The current literature implies that the use of short-segment pedicle screw fixation may be inappropriate because of its high reported failure rate. The purpose of this study is to report the short-term results of thoracolumbar burst and compression fractures treated with short-segment pedicle i...

متن کامل

The use of computer-assisted surgery as an educational tool for the training of orthopedic surgery residents in pedicle screw placement: a pilot study and survey among orthopedic residents.

BACKGROUND The training of orthopedic residents in adequate pedicle screw placement is very important. We sought to investigate orthopedic residents' perspectives on the use of computer-assisted surgery (CAS) in a training trial. METHODS Orthopedic residents were randomly assigned to independently place a screw using the free-hand technique and the CAS technique on 1 of 3 cadavers (Cobb angle...

متن کامل

Lumbosacral fixation using sacroiliac buttress screws: a modification to the Jackson technique with intrasacral rods

BACKGROUND The use of intrasacral rods has been previously reported for posterior lumbosacral fixation. However, problems associated with this technique include poor stability of the rod in the sacrum, difficulty in contouring the rod to fit the lateral sacral mass, and the complicated assembly procedure for the rod and pedicle screws in the thoracolumbar segments after insertion of the rod int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neurology India

دوره 57 6  شماره 

صفحات  -

تاریخ انتشار 2009